1.4 Receiver Specifications
Monaural Sensitivity (demodulated, de-emphasized)
3.5 µV for signal-to-noise > 50 dB
Stereo Sensitivity (19–kHz pilot frequency added)
31 µV for signal-to-noise > 50 dB
Connector Standard type N, 50
Shipping Weight 1 lb
1.5 Safety Considerations
Crown Broadcast assumes the responsibility for providing you a safe product and
safety guidelines during its use. “Safety” means protection to all individuals who
install, operate, and service the transmitter as well as protection of the transmitter
itself. To promote safety, we use standard hazard alert labeling on the product and
in this manual. Follow the associated guidelines to avoid potential hazard.
1.5.1 Dangers
DANGER represents the most severe hazard alert. Extreme bodily harm or death
will occur if DANGER guidelines are not followed.
1.5.2 Warnings
WARNING represents hazards which could result in severe injury or death.
1.5.3 Cautions
CAUTION indicates potential personal injury, or equipment or property damage if
the associated guidelines are not followed. Particular cautions in this text also
indicate unauthorized radio-frequency operation.