Operation Manual
I-Tech Series Power Amplifiers
page 38
7 AC Power Draw and Thermal Dissipation
I-Tech 6000 AC Current Draw and Thermal Dissipation:
Pink noise 12dB crest factor, bandwidth limited 22Hz to 22kHz.
Typical line impedance used.
Data based on both channels driven.
Line Current 
120VAC
Watts Out 
Per 1A 
Amp Line 
Current
Line Current 
208VAC
Watts Out 
Per 1A 
Amp Line 
Current
Line Current 
230VAC
Watts Out 
Per 1A 
Amp Line 
Current
Btu/hr kcal/hr
Idle (sleep mode) 1.0 1.0 0.95 60 205 177
Idle (awake) 2.1 1.7 1.6 225 767 660
1/8th Power Pink Noise 8 Ohms/Ch.
Typical of program material  16 Ohms Bridge
just at clip. 4 Ohms/Ch.
8 Ohms Bridge
2 Ohms/Ch.
4 Ohms Bridge
1/3rd Power Pink Noise 8 Ohms/Ch.
Typical of program material 16 Ohms Bridge
with severe clipping. 4 Ohms/Ch.
8 Ohms Bridge
2 Ohms/Ch.
4 Ohms Bridge
6.6 4.2 3.857.6 91.2 99.8 392 1338 337
593 2024 510
13.6 8.1 7.474.4 125.3 137.2
27.6 16.0 14.373.9 127.2 141.0
11.6 7.0 6.365.7 108.8 120.4
11.5 6.8 6.255.9 96.5 105.3 2373 598
1149 3921 988
579 1977 498
695
14.9 13.667.0 113.5 4173 105225.0 1223124.3
I-T6000
Load
120VAC 208VAC 230VAC
Watts 
Dissipated
Thermal Dissipation