10 US
Desulphation: Desulphation with pulsing for sulphated batteries.
Bulk: Charging where about 80% of the energy is returned. The charger delivers an
almost constant current until the battery voltage reaches the set level.
Absorption: Charging up to almost 100%. The charge current tapers and the voltage is
kept constant at the set level.
Pulse: Maintenance charge. The charging process ranges between 95% and 100%. The
batteryreceivesapulseifthevoltagefalls.Thisstagewillkeepyourbatteryinagood
conditionifitisnotbeingused.
BULK CHARGING TIME
The table shows the duration of the Bulk step up to about 80% state of charge. The time
fortheAbsorptionshouldbeadded.
Battery size (Ah) Mode Time (h)
2
2–3
8810
14
3–4
50 1214
90 23–26