EasyManua.ls Logo

Cubis stakkabox - Notes on Application

Default Icon
12 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
INTRODUCTION
2
This guide addresses the acceptable methods and details for installation of STAKKAbox™ Access Chambers. The purpose is to serve as
a guideline, and is not intended for any specic construction project. It is understood there are alternative ways that might be required
and/or recommended based on site or project conditions. CUBIS Industries reserves the right to alter these guidelines and encourages
contact with the factory or its representatives to review any possible modication to these notes prior to commencing installation. CUBIS
Industries makes no express or implied warranty or guarantee of the techniques, construction methods or materials identied herein.
The customer shall comply with all laws, regulations, codes and orders of any authority having jurisdiction over the customer and which relate
to the customer’s installation, maintenance and use of CUBIS products. If the customer’s installation or use of any products contravenes any
such laws, regulations, codes or orders of such authorities, the customer shall be responsible for the violations thereof and shall bear the costs,
expense and damages attributable to its failure to comply with the provisions of such laws, ordinances, rules, regulations, codes or orders.
Reproduction of the material herein is not permitted without the written consent of CUBIS Industries.
NOTES ON APPLICATION
This installation guide is for STAKKAbox chambers being installed in areas classed as
Groups 1, 2, 3, or 4 in accordance with European Standard EN 124 :1994.
Group 1: A15 Classication
Areas which can only be used by pedestrians and pedal cyclists.
Group 2: B125 Classication
Footways, pedestrian areas and comparable areas, car parks or parking decks.
Group 3: C250 Classication
Areas which when measured from the kerb edge extend a maximum of 0.5m into the carriageway and a
maximum of 0.2m into the footway.
Group 4: D400 Classication
Roadways, carriageways and areas used by fast moving vehicular trac.
This means that CUBIS chambers can, depending on how they are installed be situated in either the footway or the road.