EQUIPMENT AND ADDITIONAL MATERIALS
In addition to the STAKKAbox™ supplied, in order to complete an installation you will need the following:
EQUIPMENT
1. The means of excavating a hole; mechanical digger, pneumatic hammer etc. depending on the ground conditions and size
of chamber being installed.
2. Shovel or spade.
3. Means of compacting base and surrounding material.
Please refer to the “Specication for the Reinstatement of Openings in Highways - Appendix A8”
4. Builders trowel.
5. Straight edge/level.
6. Handsaw.
Furthermore if duct entries are to be cut on site:
7. Hole saw (Sized to the outside diameter of the duct to be installed).
8. A power drill (Compressed air, battery or 110v).
9. Bracing if type and size of chamber requires (See Table 1).
Materials
1. Base materials (See Table 1).
2. Backll material (See Table 1).
3. Bedding mortar/resin epoxy mortar.
FRAME AND COVER
A frame and cover must be installed, specied to the correct loading as dictated by European standards or any other relevant authority.
CUBIS Industries manufacture a range of covers and frames engineered to work in conjunction with its chambers. Covers and frames that are
not supplied by CUBIS should be agreed to be t for purpose prior to installation as this might adversely aect the quality of the installation.
HEALTH AND SAFETY
In areas where the public have access, the site should be properly signed and guarded in accordance with the Safety at
Street Works and Road Works code of practice (NRSWA 1991) or equivalent national standard.
Additionally, all other safety precautions required by legislation, the customer and as specied by the contract, the Local
Authorities, other landowners and the Police should be observed at all times.
Before any excavation takes place, all necessary precautions to locate/protect buried services in the location of the
chamber should be taken.
This document is a general installation guide for the following product ranges: STAKKAbox™ ULTIMA, STAKKAbox™ MODULA, STAKKAbox™
Fortress Footway, STAKKAbox™ Fortress Carriageway.