03/2008 - Art. Nr. 13 013 477C
C120, C160, C210 GX507/8
Operating instructions
Gas burners ......................................... 2-19
Инструкция по эксплуатации
Газовая горелка ............................... 38-55
Betriebsanleitung
Gasbrenner ........................................ 20-37
Библиотека СОК

Table of Contents

Questions and Answers

  • A
    Ashley ChapmanAug 6, 2025
    Why does my Cuenod C160 GX507/8 burner stop and nothing happens?
    • S
      samuel65Aug 6, 2025
      If your Cuenod Indoor Fireplace burner stops and nothing happens, it could be due to several reasons: insufficient gas pressure (adjust distribution pressure), a misadjusted or faulty gas pressure switch (check or replace it), a foreign body in the pressure take-off pipe (clean the pipes without pressurized fluid), or misadjusted/faulty thermostats (adjust or replace them).
  • D
    Diana WatsonAug 14, 2025
    What to do if my Cuenod Indoor Fireplace unit shows [ [ [ + \ \ [ [ [ [ + \?
    • S
      Sharon CopelandAug 14, 2025
      If your Cuenod Indoor Fireplace unit displays '[ [ [ + \ \ [ [ [ [ + \', it could be due to the air pressure switch. The contact may not close (check the pressure take-off for any foreign bodies and the wiring) or the contact opens during start-up or operation (adjust or change the pressure switch).
  • A
    Andre ThompsonAug 18, 2025
    Why Cuenod Indoor Fireplace burner doesn't start after thermostatic closure?
    • M
      matthew79Aug 18, 2025
      If your Cuenod Indoor Fireplace burner doesn't start after thermostatic closure and the unit doesn't signal any fault, it may be due to a low or missing power supply (check the source of low or missing voltage) or a faulty unit (change the unit).
  • L
    Larry LunaAug 22, 2025
    What does it mean if my Cuenod C160 GX507/8 Indoor Fireplace unit shows [ [ + \ \ \?
    • A
      Amber FrancoAug 23, 2025
      If your Cuenod Indoor Fireplace unit displays '[ [ + \ \ \', it could be due to a spurious light during the surveillance phase (change the valve) or, in the event of a cell burner, a faulty cell (change the cell).
  • A
    Amanda KingAug 27, 2025
    What does it mean when my Cuenod Indoor Fireplace unit displays \ \ + [ [ [?
    • L
      Luis FoxAug 27, 2025
      If your Cuenod Indoor Fireplace unit displays '\ \ + [ [ [', it indicates that the air pressure switch contact is welded. You should change or adjust the pressure switch.
  • J
    Jessica TuckerAug 31, 2025
    What to do if Cuenod Indoor Fireplace burner starts briefly then stops and shows [ [ 9 \ \ \ - \ \ \ \?
    • M
      Melanie MurrayAug 31, 2025
      If the burner of your Cuenod Indoor Fireplace starts briefly when powered up, then stops and shows the signal '[ [ 9 \ \ \ - \ \ \ \', it means the unit has been purposely shut down. Reset the unit.
  • K
    kelly87Nov 9, 2025
    What to do if Cuenod C160 GX507/8 Indoor Fireplace unit is on [ + \ \ \ \?
    • D
      Donald ChambersNov 9, 2025
      If your Cuenod Indoor Fireplace unit is showing '[ + \ \ \ \' and not working, it might be due to several reasons: * No flame signal at the end of safety time or an unsuitable gas flow rate: Adjust the gas flow rate. * Faulty flame monitoring circuit: Check the state and position of the ionization probe in relation to mass. * No ignition arc: Check the state and connections of the ionization circuit (cable and measuring bridge). * Ignition electrode(s) short-circuiting: Adjust, clean, or replace the electrodes. * Damaged or faulty ignition cables: Connect or replace the cables. * Faulty ignition transformer: Replace the ignition transformer. * Control unit issue: Replace the transformer or change the control unit. * Electromagnetic valves not opening: Check the wiring betw...

Summary

General information

Guarantee, safety

Instructions and regulations for installation and start-up, manufacturer liability.

Installation

Start-up

Preliminary check-up and leakage test

Essential pre-start checks, including voltage, polarity, and leakage testing.

MBVEF gas valve description & settings

Description and settings of the MBVEF gas valve, including its components and pressure adjustments.

VGD gas valve SKP75 regulator description & settings

Details on the VGD gas valve and SKP75 regulator, their function and preset values.

Gas valve leakage controller description & settings

Working principle, installation, and testing of the leakage controller VPS 504 S02.

SG 513 control & safety unit diagram

Characteristics and operation diagram of the SG 513 control and safety unit.

Working cycle test, Firing, and safety unit checks

Detailed procedures for burner working cycle test, firing, and safety unit checks.

Functions

Troubleshooting

Burner stops and related issues

Troubleshooting guide for burner stopping issues, including gas pressure and thermostat faults.

Unit status signals and causes

Interpreting unit status signals (light signals) and identifying causes for faults.

Cuenod C160 GX507/8 Specifications

General IconGeneral
ModelC160 GX507/8
CategoryIndoor Fireplace