C120, C160, C210 GX507/8
Operating instructions
Gas burners ......................................... 2-19
Инструкция по эксплуатации
Газовая горелка ............................... 38-55
Betriebsanleitung
Gasbrenner ........................................ 20-37
Библиотека СОК

Table of Contents

Questions and Answers

  • T
    Taylor HendersonAug 5, 2025
    Why does my Cuenod Indoor Fireplace burner stop and nothing happens?
    • E
      Elizabeth JonesAug 5, 2025
      If your Cuenod Indoor Fireplace burner stops and nothing happens, it could be due to several reasons: insufficient gas pressure (adjust distribution pressure), a misadjusted or faulty gas pressure switch (check or replace it), a foreign body in the pressure take-off pipe (clean the pipes without pressurized fluid), or misadjusted/faulty thermostats (adjust or replace them).
  • C
    Chad FlynnAug 14, 2025
    What to do if my Cuenod C210 GX507/8 unit shows [ [ [ + \ \ [ [ [ [ + \?
    • A
      amyscottAug 14, 2025
      If your Cuenod Indoor Fireplace unit displays '[ [ [ + \ \ [ [ [ [ + \', it could be due to the air pressure switch. The contact may not close (check the pressure take-off for any foreign bodies and the wiring) or the contact opens during start-up or operation (adjust or change the pressure switch).
  • B
    babbottAug 18, 2025
    Why Cuenod C210 GX507/8 Indoor Fireplace burner doesn't start after thermostatic closure?
    • S
      salazarkentAug 18, 2025
      If your Cuenod Indoor Fireplace burner doesn't start after thermostatic closure and the unit doesn't signal any fault, it may be due to a low or missing power supply (check the source of low or missing voltage) or a faulty unit (change the unit).
  • J
    jameslunaAug 22, 2025
    What does it mean if my Cuenod C210 GX507/8 unit shows [ [ + \ \ \?
    • N
      Norman BurgessAug 23, 2025
      If your Cuenod Indoor Fireplace unit displays '[ [ + \ \ \', it could be due to a spurious light during the surveillance phase (change the valve) or, in the event of a cell burner, a faulty cell (change the cell).
  • L
    Lisa WilsonAug 27, 2025
    What does it mean when my Cuenod C210 GX507/8 Indoor Fireplace unit displays \ \ + [ [ [?
    • M
      matthew14Aug 27, 2025
      If your Cuenod Indoor Fireplace unit displays '\ \ + [ [ [', it indicates that the air pressure switch contact is welded. You should change or adjust the pressure switch.
  • V
    Victor MckeeAug 31, 2025
    What to do if Cuenod Indoor Fireplace burner starts briefly then stops and shows [ [ 9 \ \ \ - \ \ \ \?
    • B
      Brian CollinsAug 31, 2025
      If the burner of your Cuenod Indoor Fireplace starts briefly when powered up, then stops and shows the signal '[ [ 9 \ \ \ - \ \ \ \', it means the unit has been purposely shut down. Reset the unit.
  • H
    Heidi SellersNov 9, 2025
    What to do if Cuenod C210 GX507/8 Indoor Fireplace unit is on [ + \ \ \ \?
    • A
      Alyssa ValentineNov 9, 2025
      If your Cuenod Indoor Fireplace unit is showing '[ + \ \ \ \' and not working, it might be due to several reasons: * No flame signal at the end of safety time or an unsuitable gas flow rate: Adjust the gas flow rate. * Faulty flame monitoring circuit: Check the state and position of the ionization probe in relation to mass. * No ignition arc: Check the state and connections of the ionization circuit (cable and measuring bridge). * Ignition electrode(s) short-circuiting: Adjust, clean, or replace the electrodes. * Damaged or faulty ignition cables: Connect or replace the cables. * Faulty ignition transformer: Replace the ignition transformer. * Control unit issue: Replace the transformer or change the control unit. * Electromagnetic valves not opening: Check the wiring betw...

Summary

General Information

Guarantee and Safety

Essential safety guidelines and warranty information for burner operation.

Start-up Procedures

Preliminary Checks and Leakage Test

Essential pre-startup checks, including system integrity and leakage detection.

Control and Safety Unit Characteristics: SG 513 Operation Diagram

Characteristics and operational diagram of the SG 513 control and safety unit.

Working Cycle Test

Procedure to test the burner's operational cycle and safety interlocks.

Firing the Burner

Guidelines and critical checks required before and during burner ignition.

Setting and Checking Safety Units

Procedures for setting and verifying gas pressure and air pressure safety switches.

Troubleshooting Guide