What to do if there is no flame signal at end of safety time in Cuenod Indoor Fireplace?
- SSteven MullinsAug 15, 2025
If there's no flame signal at the end of the safety time for your Cuenod Indoor Fireplace, here's what you can check: * Adjust the gas flow stage if it's unsuitable. * Inspect the ionization circuit's condition and connections, including the cable and measuring bridge. * Adjust, clean, or replace the electrodes if there's no ignition arc. * Connect or replace the cable(s) if the ignition electrode(s) are short-circuiting. * Replace damaged or faulty ignition cable(s). * Replace the ignition transformer if it's faulty. * Change the control unit. * Check the wiring between the unit, servomotor, and valves if the electromagnetic valves aren't opening. * Check or change the coil if there's mechanical jamming in the valves. * Change the valve.