33
Hints and Tips
Fault Code
Indicator light flashes
Possible Causes Remedy
START/
PAUSE
Inadequate water
supply
Make sure the water input tap is
totally open and that there is no
water cut.
Close the water input tap,
separate the water input hose
from the tap and clean the filter at
the connection end of the hose.
Restart your machine, contact
your service
agent if the error resumes.
Shut off valve fault Close the tap.
Contact the service.
The waste water
in the machine
cannot be
discharged
Water discharge hose is clogged.
The filters of your machine might
be clogged.
Power off-on your machine and
activate the program cancellation
command.
If the error continues, contact
your service agent.
Intended water
temperature could
not be reached
faulty heater and
heater sensor
Contact your service agent.
Alarm is active
against water
overflow
Power off your machine and close
the tap.
Contact your service agent.
Faulty electronic
card
Contact your service agent.
Repairs should only be carried out by a qualified technician in strict accordance with current
local and national safety regulations. Unauthorised or incorrect repairs could cause personal
injury or damage to the unit.
Before calling for service, please refer to Hints and Tips to solve some general problems
by yourself.
Currys Essentials Freestanding Dishwasher CDW45W18 Manual.indd 33 28/03/2018 16:10