EasyManua.ls Logo

Curtis Instruments 908 - Model Encodement; Case Style Options; Voltage Options; Reset Profile Options

Default Icon
11 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2 3
Example: Model 908 R 2448 D P J A O
Case Style
Voltage
Reset
Discharge
Output
Special
Options
1 3 5
2 4 6
Artwork
7
Case Style Options:
R = Round (52mm)
1
Voltage Options:
2
Reset Profile Options
3
1. MODEL ENCODEMENT
Single Dual
12 24/36
24 24/48
36 36/48
48 72/80
72
80
Letter
Code
Volts per Cell
Open Circuit
Reset
Charge
Tracking
Reset Full
Charge
Tracking
Reset
Empty
B 2.090 2.35 2.10
C 2.135 2.400 2.10
D 2.060 2.32 2.10
G 2.090 2.40 2.10
K 1.928 2.167 2.10
N 1.980 2.230 2.10
T 2.028 2.28 2.10
Y 2.083 2.167 2.10