Curtis 1356/1356P CAN Expansion Module Manual, Rev. A
ENCODER MONITOR MENU
ALLOWABLE
PARAMETER RANGE DESCRIPTION
Pulse Counts -2
29
4 2
29
-1 Current encoder pulse counts.
Negative counts indicate the encoder is running
in the reverse direction of the zero position.
RPM
0 65535 rpm Displays RPM, when the encoder type
isconguredasRPMmode.
Position -32.768 32.767 m Displays position, when the encoder type
isconguredasPositionmode.
Negative counts indicate the encoder ia running
in the reverse direction of the zero position.
7 — PROGRAMMER: MONITOR MENUS
POWER SUPPLY OUTPUT MONITOR MENU
ALLOWABLE
PARAMETER RANGE DESCRIPTION
+5V 0.0 6.3 V Voltage of the +5V output.
+12V 0.0 16.0 V Voltage of the +12V output.
EXT Current 0 250 mA Combined current of the external +12V and +5V
power supplies.
BATTERY VOLTAGE MONITOR MENU
ALLOWABLE
PARAMETER RANGE DESCRIPTION
Battery Voltage 0.0 120.0 V Voltage of the battery.
HOUR METER MONITOR MENU
ALLOWABLE
PARAMETER RANGE DESCRIPTION
Hours 0 65535 h Present hours of the hour meter. The hour meter
runs all the time the 1356 /1356P is powered on.
Minutes 0 59 min Present minutes of the hour meter.
Fault Menu
e Curtis programmer provides a convenient way to access fault information;
see Section 6: Faults and Diagnostics. e programmer displays the faults by
name. It displays all faults that are currently set and also a history of all the
faults that have been set since the history log was last cleared.