Programming Options
Your Curtis CAFEPC dispenser is factory preset for optimal performance. Generally, there will not be a need to
change the programming. If necessary, the following operating parameters can be changed:
• Water temperature
• Manual Dispense Mode/Preset Dispense Mode
• Product % Ratio
Changing the Water Temperature (Factory Default: 190°F-standard units, 100°F-iced cappuccino units)
The following steps can also be used to read the existing temperature setting. The water temperature range is 80°
to 204°F.
1 The rear toggle switch must be in the ON position and the ready light(s) must be on.
2 Press and hold the STOP/WASH button (for about 10 seconds) until all the lights start blinking, then release.
3 1SFTTUIF45018"4)CVUUPOBTFDPOEUJNFGPSBCPVUBTFDPOET5IF45018"4)MJHIUXJMMCFHJOUPnBTIB
repeated pattern.
4 Read the existing temperature setting according to TABLE 1. After a periodic pause, the number of (quick)
nBTIFTSFQSFTFOUTUIFUFNQFSBUVSFTFUUJOHTUBSUJOHBU¡'nBTIFTSFQSFTFOUTUIFNBYJNVNUFNQFSBUVSFPG
204°F.
5 To exit without changing the temperature, press one of the PUSH buttons. To change the temperature, press and
holdUIF45018"4)CVUUPOXIJMFXBUDIJOHUIFOVNCFSPGnBTIFT3FMFBTFUIF45018"4)CVUUPOXIFOUIF
desired temperature is indicated according to TABLE 1.
6 Press one of the PUSH buttons to set and exit.
PROGRAMMING GUIDE PG14
$"'&1$130(3"..*/((6*%&ø /$
# of Flashes Temperature # of Flashes Temperature
1 80°F/27°C 10 185°F/85°C
2 85°F/29°C 11 190°F/88°C
3 90°F/32°C 12 192°F/89°C
4 95°F/35°C 13 194°F/90°C
5 100°F/38°C 14 196°F/91°C
6 105°F/41°C 15 198°F/92°C
7 110°F/43°C 16 200°F/93°C
8 120°F/49°C 17 202°F/94°C
9 140°F/60°C 18 204°F/96°C
TABLE 1
Control panel design varies based on model
STOP/WASH light