4
Your Curtis G3/Gold Cup Series is factory preset for optimum performance.
After connection to water and power; the rear toggle switch must be on. You will hear a beep sound, indicating power is available to the controller.
The control displays . Press ON/OFF button and the screen will display . After three seconds, is displayed.
Waterwillllthetank(approximately2-3minutesdependingonwaterowrate).Whentheproperlevelisreached willappearonthescreen.It
takes approximately 20 minutes to reach the set point temperature.
Control will display when temperature reaches the set point. The unit is now ready to brew.
<CBHVT>
CURTIS
CURTIS
CURTIS
Ready to Brew
CURTIS
Filling
CURTIS
Heating
Program Menus
From Program Menus press ►. The display will show the next feature Coffee Recipes.
Coffee Recipes (factory set to Gourmet STD)
Press to select. If selected, press or to choose a coffee recipe: Gourmet STD, Light Roast, Dark Roast, High Yield,
Filter Pack or Decaf. Press to select the desired recipe.
Non-Brew Program
Press to select or to pass by these options and continue to the next group. The selections for Non-Brew Program
are listed below.
Temperature (factory set to 204ºF)
Press to select. Then press or to move to the desired temperature, then to set and exit. The temperature is
programmablefrom170ºFto208ºFin2-degreeincrements.
Energy Save Mode (factory set to OFF)
Press to select. Then press or tochooseON,OFForON140ºF,then to set and exit. When ON, the brewer will
automatically shut off 4 hours after the last brew. When the feature is OFF, the brewer does not utilize the energy saving mode.
IntheON140ºFposition,thetemperaturelowersto140ºF,iftheunithasnotbrewedin4hours.Thisfeaturewillsaveenergyby
maintaining a lower temperature in the tank in periods of non-operation.
Brew Count Odom
Press to display total brew cycles. Press EX or Reset.
Brew Count Total
Press to select. This feature shows the total gallons and total brew cycles on the brewer. It cannot be reset.
Temperature
Energy Save Mode
Brew Count Odom
Coffee Recipes
Non-Brew Program
Brew Count Total
Programming the Universal Control Module (UCM)
Turn off the control panel by pressing the ON/OFF button. Press and hold the bottom/right coffee brew button (#4 in illustration) and then press and release the ON/OFF button.
Continue holding the bottom-right brew button. The screen will display , wait until is displayed. Enter the 4-digit access code, the code corresponds to
thebuttonsillustratedbelow.Thedefaultcodesetatthefactoryis1-2-3-4.
After the 4-digit code is entered, will be displayed. You can now enter the program menu features.
Enter Code
– – – –
Program Menus
< Select >
Entering
Programming Mode
PROGRAM MENUS COMBO BREWER
431 2
Scroll left (button 1)
Select or Enter to save new parameter (button 2)
Scroll right (button 3)
All programming selections are performed with the
three center buttons. The symbols above and below the
buttons are: