30
User manual Curtis G3 Tea/Coffee Combo brewer
Software | Control module
Note
When Coffee Pulse Brew is on, Pre-Infuson is
disabled.
Setting Description
A Starts at beginning of brew cycle. 4
cycles of 10 seconds on and 5 seconds
off, then on until end of brew cycle.
B Starts towards end of brew cycle. 4
cycles of 5 seconds off and 4 cycles of
10 seconds on. Ends when brew cycle
ends.
C Starts at beginning of brew cycle. 5
cycles of 25 seconds on and 10 seconds
off, then on until end of brew cycle.
D Manually set. Starts at beginning
of brew cycle. Number of pulses is
adjustable from 1 to 20. Pulse on
time and off time are both adjustable
from 5 to 150 seconds, in 5 second
increments.
E Manually set. Starts at beginning
of brew cycle. Number of pulses is
adjustable from 1 to 8. Pulse on time
and off time are both adjustable from
1 to 150 seconds.
Pulse Brew Guidelines
- Filter pack type coffees typically extract better with
the A and B pulse setting.
- Decaffeinated coffees typically extract better with
the B pulse setting.
- High-yield coffees typically extract better with the C
pulse setting. Of course, any of the A, B or C settings
may be used to suit your taste profi le.
- Settings D and E are manual pulse counts.