PROGRAMMING GUIDE PG2
8$130(3"..*/((6*%&ø H
Brew Button Programming Menu (cont.)
Brew by Time - adjusts the amount of coffee brewed by time rather than by volume. The factory default
TFUUJOHTBSF-"3(&NJOTFD.&%*6.NJOTFD4."--NJOTFD0ODFBDDFTTFEQSFTT
Ż or ŹVOUJMUIFOVNCFSPGNJOVUFTJTnBTIJOH5IFOQSFTT
~ repeatedly to change the number value. Press
Ż or ŹVOUJMUIFOVNCFSPGTFDPOETJTnBTIJOH5IFOQSFTT~ repeatedly to change the number value. Press
Ż or ŹVOUJMiFYwJTnBTIJOHUIFOQSFTT~ to exit.
* Not applicable to TP1 series.
** This is the LARGE setting for TP1 series brewers.
Pre-Infusion - sets the brewer Pre-Infusion time (Pulse Brew must be off to access, the factory default setting is
%JTBCMFE1SF*OGVTJPOJODSFBTFTDPOUSPMPGDPGGFFDMBSJUZBOEFYUSBDUJPO8IFOUVSOFEPOUIFTFUUJOHSBOHFJTUP
TFDPOET0ODFBDDFTTFEQSFTTŻ or Ź to choose the desired setting, then, press ~ to exit. To turn off pulse
CSFXNPEFDIPPTFGPSUIFUJNF
When Pre-infusion is On, Pulse Brew disappears from the list of menu items.
Pulse Brew - selects the pulse brew pattern (Pre-Infusion must be off to access, the factory default setting
JT$5IFQVMTFCSFXQBUUFSOTFMFDUFEiUVOFTwPSDIBOHFTUIFnBWPSPGUIFDPGGFF0ODFBDDFTTFEQSFTTŻ or
Ź to choose the desired setting. Then, press ~ to exit.
8IFO1VMTF#SFXJT0O$PME#SFX-PDLJTTFUUPXJUIJO'¡$PGUIFXBUFSUFNQFSBUVSFMFWFMBOE
Cold Brew Lock and Pre-Infuson disappear from the list of program selections.
Pulse Brew Guidelines
• Filter pack type coffees typically extract better with the A and B pulse setting.
• Decaffeinated coffees typically extract better with the B pulse setting.
• High-yield coffees typically extract better with the C pulse setting. Of course, any of the A, B or C
TFUUJOHTNBZCFVTFEUPTVJUZPVSUBTUFQSPmMF
• Settings D and E are manual pulse counts.
By-Pass - IFMQTDPOUSPMFYUSBDUJPOXJUIMBSHFSCSFXT5IFGBDUPSZEFGBVMUTFUUJOHTBSF-"3(&GPS
51TFSJFT.&%*6.4."--0GG*USFEVDFTDPOUBDUUJNFUPBWPJEFYUSBDUJPOPGVOEFTJSBCMFCJUUFSBOE
IBSTInBWPSDPNQPVOET5IFTFUUJOHSBOHFJTUP0ODFBDDFTTFEQSFTTŻ or Ź to choose the
desired setting, then, press ~ to exit.
Language Menu - changes the language that appears on the display. The factory default setting is English. This
feature is programmable for changing and adding languages. Once accessed, press Ż or Ź to choose the
desired setting, then press ~ to exit.
continued...
Setting Description
A Toward the beginning of brew cycle: 4 cycles of 10 seconds on and 10 seconds off, then on until end of brew cycle.
B
Starts towards ends of brew cycle. 4 cycles of 10 seconds off and 4 cycles of 10 seconds on. Ends when brew
cycle ends.
C Starts at beginning of brew cycle. 5 cycles of 25 seconds on and 20 seconds off, then on until end of brew cycle.
D
Manually set. Starts at beginning of brew cycle. Number of pulses is adjustable from 1 to 20. Pulse on time and off
time are both adjustable from 5 to 150 seconds.
E
Manually set. Starts at beginning of brew cycle. Number of pulses is adjustable from 1 to 8. Pulse on time and off
time are both adjustable from 1 to 150 seconds.