32
MAINTENANCE
system. Water that is not distilled should be analyzed and, if required, filtration installed to permit the water to meet the
requirements of the water purity table.
Even if the water is colorless, odorless, tasteless and fit for drinking, the water should be analyzed to see that it does
not exceed the impurity levels specified in the table.
Automatic watering devices such as the one included in the Battery Maintenance Kit (P/N 25587-G01) can be used
with an approved water source. These watering devices are accurate, easy to use and allow for rapid filling. They also
maintain the correct electrolyte level within the battery cells. The watering device should only be used if the electrolyte
level is less than 1/2” (13 mm) above top of plates.
Water Purity Table
Impurity
Parts Per
Million
Color
Suspended
Total Solids
Calcium & Magnesium Oxides
Iron
Ammonia
Organic & Volatile Matter
Nitrites
Nitrates
Chloride
Clear
Trace
100
40
5
8
50
5
10
5
Pure Water
Valve consistently fills
to a predetermined level
Electrolyte Level
Single Battery Cell
Automatic Watering Gun
Hand Held Watering Device
Distilled Water
Dispensing valve consistently
fills to a predetermined level
Electrolyte Level
Single Battery Cell