Command Description Contents
R HUE Inquire hue setting
S SATURATION 0~60 Saturation setting
R SATURATION Inquire saturation setting
S SHARPNESS 0~30
Sharpness setting
R SHARPNESS Inquire sharpness setting
S NR 0~3 Noise reduction setting 0=OFF / 1=LOW / 2=MIDDLE / 3=HIGH
R NR Inquire noise reduction
setting
Reports the numerical equivilent for the
NR setting (as above)
S AUDIODELAY 0~3 Audio delay setting 0=OFF / 1=40ms / 2=110ms(2) / 3=50ms
R AUDIODELAY Inquire audio delay setting Reports the numeric equivilent for
AUDIODELAY setting (as above)
S AUDIOMUTE 0/1 Audio mute setting 0=ON / 1=MUTE
R AUDIOMUTE Inquire audio mute setting
S KEY LOCK 0/1 Key lock setting 0=ENABLE / 1=DISABLE
R KEY LOCK Inquire key lock setting Reports the numeric equivilent for KEY
LOCK setting (as above)
FW Firmware checking
S RESET 1 Pre-reset
S POWER 0/1 Power On/O 0=OFF / 1=ON
R POWER Power Status Reports the numeric equivilent for
POWER setting (as above)
Note: RS-232 commands will be not executed unless followed with a carriage
return and LF. Commands are case-insensitive.