6.5
RS-232 Commands
COMMAND DESCRIPTION
S SOURCE 1~2 1=PC
2=HDMI
R SOURCE Reports the numerical equivalent for
SOURCE setting (as above)
S OUTPUT 0~25 0=Native 12=1600×1200
1=640×480 13=1920×1080
2=800×600 16=1920×1200
3=1024×768 17=480p
5=1360×768 18=720p@60
6=1280×720 19=1080p@60
7=1280×800 20=1080i@60
8=1280×1024 22=576p
9=1440×900 23=720p@50
10=1400×1050 24=1080p@50
11=1680×1050 25=1080i@50
R OUTPUT Reports the numerical equivalent for OUTPUT
setting (as above)
S SIZE 0~6 0=OVERSCAN 4=LETTER BOX
1=FULL 5=UNDER 2
2=BEST FIT 6=UNDER 1
3=PAN SCAN
R SIZE Reports the numerical equivalent for SIZE
setting (as above)
S CONTRAST 0~60 Setups the numerical equivalent for
CONTRAST setting (as left)
R CONTRAST Reports the numerical equivalent for
CONTRAST setting
S BRIGHTNESS 0~60 Setups the numerical equivalent for
BRIGHTNESS setting (as left)
R BRIGHTNESS Reports the numerical equivalent for
BRIGHTNESS setting
S HUE 0~60 Setups the numerical equivalent for HUE
setting (as left)