together for 3 seconds to enter setting mode,
Then press to switch P level setting from P01 to P20
and press or to choose the right data code for each P
level setting.
P Level Setting Code Definition
P01: Brightness, Range 1 is darkest, 3 is brightest;
P02: Speed Unit, Range 0 is KM, 1 is Mile
P03: Working Voltage, Range: 24V,36V, 48V;
P04: Bike Auto Shutting-down time, it means if you do not operate the bike computer or use
the e-bike within the minutes range from 1 to 60 minutes, the bike computer will shut down
automatically;
P05: PAS preference, Range: 0 only shows 1-3 levels; 1 shows 1-5 levels. ( Just showing
PAS level number are different, but top and lowest level power is the same, such as 3= 5 in
different working modes);
P06: Wheel/rim diameter inch, Range: 20/22/26/28 ( Normally, if 20 inch rim, setting number
will be 22inch)
P07: Speed Monitor setting, this technical setting is no use for customer but only for engineer
setting, please do not modify or change the setting. Range: 1-100;
P08: Speed limited setting. Range: 1-100KM, If 100KM, means there is no limited for speed