The engine does not develop full power
Too much oil remaining in the crankcase
Fuel supply inadequate (less than 2,5 Bar)
Refuel with prescribed grade fuel.
Tighten all connections. Replace defective parts.
Insufficient oil in oil tank
Check oil level and fill if necessary
Oil remains in engine and doesn’t circulate
Check oil return line to tank
Check the pressure control valve.
Defective oil pressure gauge
Replace the oil pressure gauge.
Bearings defective (no oil pressure)
A major overhaul is necessary.
The engine does not stop immediately