Do you have a question about the Daavlin UV Series and is the answer not in the manual?
Treatment Type | Phototherapy |
---|---|
Application | Psoriasis, Vitiligo, Eczema |
Safety Features | emergency stop |
Wavelength Range | 311-313 nm |
Power Supply | AC 120V/230V, 50/60Hz |
Power Consumption | Varies depending on model |
Dimensions | Varies by model |
Weight | Varies by model |
Treatment Area | Full body |
Details on safety key code labels and FlexRx™ software indicators.
Illustrates and explains warning and danger labels affixed to the device.
Chart detailing device symbols and their meanings.
Explanation of UV Risk Group 2 labels for CE devices.
Explains the safety backup time feature in the Integrated Dosimetry System.
Procedure for measuring the device's power output.
Step-by-step guide for setting up a treatment using the dosimeter.
Details on pausing, resuming, checking output, and ending treatments.
Specifies the operational range and accuracy of the flex dosimeter.
Explains the safety backup time for the 1 Series Integrated Dosimetry System.
Procedure for measuring power output for the 1 Series at different distances.
Step-by-step guide for setting up a treatment on the 1 Series.
Details on pausing, resuming, and ending treatments for the 1 Series.
Specifies the operational range and accuracy for the 1 Series dosimeter.
Guidance on calculating treatment times using time equivalents.
Step-by-step instructions for setting treatment time on the digital timer.
Details on pausing, resuming, and ending treatments with the digital timer.
Specifies the operational range and accuracy of the flex timer.
Guidance on calculating treatment times for the 1 Series timer.
Step-by-step instructions for setting treatment time on the 1 Series timer.
Details on pausing, resuming, and ending treatments for the 1 Series digital timer.
Specifies the operational range and accuracy for the 1 Series flex timer.
Specifies electrical requirements for domestic and non-CE UV Series units.
Specifies electrical requirements for European CE UV Series units.
Location and function of the circuit breaker on UV Series units.
Instructions for unpacking and assembling UV Series devices.
Guidance on optimal patient positioning within the UV Series unit.
Procedure for safe removal and replacement of UV Series lamps.
Details electrical requirements for 7 Series units based on lamp configuration.
Instructions for unpacking and assembling 7 Series devices.
Guidance on optimal patient positioning within the 7 Series unit.
Procedure for safe removal and replacement of 7 Series lamps.
Details electrical requirements for M Series units.
Instructions for unpacking and assembling M Series devices.
Specific operational notes for M Series units.
Guidance on optimal patient positioning within the M Series unit.
Procedure for safe removal and replacement of M Series lamps.
Details electrical requirements for 4 Series units.
Instructions for unpacking and assembling 4 Series devices.
Guidance on optimal patient positioning within the 4 Series unit.
Procedure for safe removal and replacement of 4 Series lamps.
Details electrical requirements for 1 Series units.
Instructions for unpacking and assembling 1 Series devices.
Guidance on patient positioning for hand, foot, and larger area treatments.
Procedure for safe removal and replacement of 1 Series lamps.
Notes on treatment distance and calibration for dosimeter-equipped 1 Series units.
Notes on treatment distances and calibration for timer-equipped 1 Series units.
UVA clearing phase treatment protocols for skin types I through III.
UVA clearing phase treatment protocols for skin types IV through VI.
Protocols for UVA maintenance phase treatments.
LO Dose Broad Band UVB clearing phase protocols for all skin types.
LO Dose Broad Band UVB maintenance phase protocols for all skin types.
HI Dose Broad Band UVB clearing phase protocols for skin types I-II and III-VI.
HI Dose Broad Band UVB maintenance phase protocols for all skin types.
LO Dose Narrow Band UVB clearing phase protocols for all skin types.
LO Dose Narrow Band UVB maintenance phase protocols for all skin types.
HI Dose Narrow Band UVB clearing phase protocols for various skin types.
HI Dose Narrow Band UVB maintenance phase protocols for all skin types.
Schedule outlining recommended maintenance actions and their frequencies.
Procedures for general cleaning, low-level, and high-level disinfection.
Details the automated self-tests performed by the flex controller upon startup.
Explanation of error codes related to range errors in the flex controller.
Describes various sensing error codes (EE00-EE04) and their causes.
Details the terms and conditions of the limited warranty for Daavlin equipment.
Specifies what is covered and excluded under the limited warranty.
Outlines the purchaser's responsibilities for warranty claims.
Describes the process for obtaining warranty service and repairs.
Contact information for proper disposal instructions.
Information on extended warranties and aftermarket sales.
Provides contact details for Daavlin USA and overseas.