Do you have a question about the Daavlin 7 Series and is the answer not in the manual?
Device Type | Phototherapy Device |
---|---|
Model | 7 Series |
Application | Treatment of skin conditions such as psoriasis, vitiligo, and eczema |
Light Source | Fluorescent lamps |
Power Supply | AC |
Wavelength | 311 nm (narrowband UVB) |
UVB | Narrowband |
Treatment Area | Full Body |
Power Requirements | 120V |
Weight | Varies by model configuration |
Dimensions | Varies depending on configuration |
Certifications | CE Marked |
Treatment Type | Narrowband UVB Phototherapy |
Classification of optical radiation sources according to photobiological hazard, including Risk Group 2.
Explanation of the safety backup time feature for dose delivery.
Procedure to determine the device's power output for calibration.
Step-by-step guide for setting up a phototherapy treatment session.
Functions like pausing, checking power output, and ending treatments.
Specific notes regarding backup time entry and system beeps.
Specifications for backup time range, dose range, accuracy, and calibration.
Explanation of the safety backup time for the 1 Series dosimeter.
Procedure to measure power output for the 1 Series device.
Guide to setting up a treatment session on the 1 Series.
Instructions on how to repeat a previously administered treatment.
Special functions for the 1 Series integrated dosimeter.
Specific operational notes for the 1 Series dosimeter.
Range and accuracy specifications for the 1 Series Flex Dosimeter.
Method for determining appropriate treatment time using time charts.
Step-by-step guide to setting the treatment time on the digital timer.
Functions like pausing, ending, and checking lamp age.
Notes regarding maximum treatment time and audio feedback.
How to determine treatment time for the 1 Series using time charts.
Guide to setting up treatment time on the 1 Series digital timer.
Functions specific to the 1 Series digital timer.
Notes on maximum treatment time for the 1 Series timer.
Electrical specifications for domestic UV Series X and T units.
Electrical specifications for European CE UV Series X and T units.
Location and operation of the main disconnect circuit breaker.
Steps for unpacking and assembling the UV Series device.
Electrical specifications for the 7 Series X and T units.
Instructions for unpacking and assembling the 7 Series device.
Guidance on patient positioning for 7 Series treatments.
Procedures for replacing lamps in the 7 Series device.
Electrical specifications for the M Series X and T units.
Instructions for unpacking and assembling the M Series device.
Important operational notes for the M Series hood lamps.
Guidance on patient positioning for M Series treatments.
Procedures for replacing lamps in the M Series device.
Electrical specifications for the 4 Series device.
Instructions for unpacking and assembling the 4 Series device.
Guidance on patient positioning for 4 Series treatments.
Procedures for replacing lamps in the 4 Series device.
Electrical specifications for the 1 Series X and T units.
Instructions for unpacking and assembling the 1 Series device.
Guidance on patient positioning for 1 Series treatments.
Procedures for replacing lamps in the 1 Series device.
Special notes for 1 Series units featuring integrated dosimetry.
Explanation of treatment distances for the 1 Series device.
Information regarding the device's calibration output certificate.
Special notes for 1 Series units with a digital timer.
Correlation between treatment distances and calibration certificate values.
Detailed UVA clearing phase protocols for skin types I through III.
Detailed UVA clearing phase protocols for skin types IV through VI.
Protocols for UVA maintenance phase treatments.
Dose limits for UVA maintenance and as-required protocols.
Protocols for LO Dose Broad Band UVB clearing phase treatments.
Protocols for LO Dose Broad Band UVB maintenance phase treatments.
Dose limits for LO Dose Broad Band UVB maintenance protocols.
Protocols for HI Dose Broad Band UVB clearing phase treatments.
Protocols for HI Dose Broad Band UVB maintenance phase treatments.
Protocols for LO Dose Narrow Band UVB clearing phase treatments.
Protocols for LO Dose Narrow Band UVB maintenance phase treatments.
Dose limits for LO Dose Narrow Band UVB maintenance protocols.
Protocols for HI Dose Narrow Band UVB clearing phase treatments.
Protocols for HI Dose Narrow Band UVB maintenance phase treatments.
Dose limits for HI Dose Narrow Band UVB maintenance protocols.
Schedule for unit maintenance including dusting, cleaning, and calibration.
Procedures for general cleaning and disinfection of the unit.
Protocol for high-level disinfection between patient uses.
Steps to reset the lamp age counter after lamp replacement.
Explanation of the automated self-test performed on power-up.
Meaning of error codes related to range errors in controller variables.
Explanation of various sensing errors and their troubleshooting steps.
Details of the limited warranty provided for the equipment.
Scope of warranty coverage and exclusions.
Purchaser's responsibilities when requesting warranty service.
Procedures and terms for Daavlin warranty service.
Instructions for proper disposal of the unit and accessories.
Information on extended warranties and other available services.
Contact details and addresses for Daavlin.