Weighing Mode 2. Packer Mode (F21-02 setting)
Relay “ON” when “Runinput, OFFwhen the weight reaches to set value.
1. Set value setting
LOW (LOW value), HIGH (High value High Free Fall)
2. Finish relay output delay time(t1) setting : F-Function 22
3. Finish relay output “ON” time(t2) setting : F-Function 23
4. Relay Output
Relay
Contents
Relay
Contents
LOW
RUN input : ON
Current weight=LOW(OFF)
FINISH
After “t1” time,
“On” during “t2” time
HIGH
RUN input : ON
Current weight=HIGH(OFF)
NEAR
ZERO
Within “EMPTY” range (ON)
LOW
HIGH Free Fall
Finish Point
t1
Weight
Near Zero
RUN(IN)
LOW
HIGH
FINISH
Near Zero
t2
Output 1
Output 4
Output 2
Output 3