◆ Weighing Mode 2. Packer Mode (F21-02 setting)
Relay “ON” when “Run” input, “OFF” when the weight reaches to set value.
1. Set value setting
LOW (LOW value), HIGH (High value – High Free Fall)
2. Finish relay output delay time(t1) setting : F-Function 22
3. Finish relay output “ON” time(t2) setting : F-Function 23
4. Relay Output
LOW
Current weight=LOW(OFF)
FINISH
“On” during “t2” time
HIGH
Current weight=HIGH(OFF)
ZERO
Within “EMPTY” range (ON)
LOW
Weight
Near Zero
RUN(IN)
LOW
HIGH
FINISH
Output 1
Output 2
Output 3
26 / 49