“FINISH Relay” delay time(t1) setting (Under F21- 01, 02 setting)
F22 10
00
+
99
After current weight is reached to FINAL, you can set some delay
time of “FINISH relay ON time.
“00” setting : At Steady point, FINISH relay output
“20” setting : After 2.0sec from Steady point, FINISH relay output
“99” setting : After 9.9sec from Steady point, FINISH relay output
FINISH Relay “ON” time(t2) setting (Under F21-01, 02setting
F23 10
00
+
99
You can set duration time for FINISH relay.
“01” setting : FINISH relay will be “ON during 0.1sec.
“20” setting : FINISH relay will be “ON” during 2.0sec.
“STEADY” Judging delay time(t3) setting (Only for F21-03, Check mode1.)
F24 10
00
+
99
After current weight is reached to each set point, you can set some
delay time of “STEADY”.
“00” setting : At Steady point, FINISH relay output
“20” setting : During 2.0sec, hold “Steady” relay
“99” setting : During 9.9sec, hold “Steady” relay
“STEADY” Judging “ON” time(t4) setting (Only for F21-03, Check mode1.)
F25 10
00
+
99
After current weight is reached to each set point, you can set some
delay time of “STEADY” or after output of each set point relay
.
“00” setting : During or after the weight reaches to “Empty Range”.
“20” setting : During or after 2.0sec, Relay will be on.
“99” setting : During or after 9.9sec, Relay will be on.
Com-Out3
Steady point
t4
Com-Out3
Steady point
t3
ComOut3
Steady point
t2
FINISH Relay
ComOut3
Steady point
FINISH Relay
29 / 49