EasyManua.ls Logo

Dacor DDW24S - Troubleshooting

Dacor DDW24S
24 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9
Service Manual - Dishwasher Models DDW24S, RDW24I and RDW24S
Cycle Process Description
Presented below is a detailed description of the Quick cycle process. This description applies to a DDW24S with no options selected. If
the component test in the service menu is not sufficient to identify a fault, you can run the Quick cycle and compare the results with the
process description below. If they are in agreement this indicates a correctly functioning control unit.
Step Component Time Notes
Main wash
1 Drain process 6 sec 12-16 sec when restarting or if an earlier program was interrupted
2 Inlet process 255 sec Maximum time. Inlet time is controlled by a flow meter**
3 Circ. pump 3 sec
4 Pause 30 sec If water temperature is >30°C ECO program starts (DDW24S)
5 Circ. pump 30 sec
6 Pause 5 sec
If ECO is set Circ. pump 120 sec
Drain process 120 sec Maximum time. Time is controlled by level sensor***
Inlet process 255 sec Maximum time. Inlet time is controlled by a flow meter**
7 Circ. pump + dispenser 10 sec
8 Circ. pump + element 60°C If ECO 30°C
9 Circ. pump 30 sec
10 Cleaning cycle for container 90 sec Maximum time 90 sec. Minimum time 76 sec*
11 Drain process 120 sec Maximum time. Time is controlled by level sensor***
1st rinse
12 Inlet process 255 sec Maximum time. Inlet time is controlled by a flow meter**
13 Circ. pump 3 sec
14 Pause 5 sec
15 Circ. pump 3 sec
16 Drain process 120 sec Maximum time. Time is controlled by level sensor***
2nd rinse
17 Inlet process 255 sec Maximum time. Inlet time is controlled by a flow meter**
18 Circ. pump 150 sec
19 Cleaning cycle for container 90 sec Maximum time 90 sec. Minimum time 76 sec*
20 Drain process 120 sec Maximum time. Time is controlled by level sensor***
3rd rinse
21 Inlet process 255 sec Maximum time. Inlet time is controlled by a flow meter**
22 Circ. pump 60 sec
23 Circ. pump + element 60°C
24 Circ. pump + dispenser 10 sec Pulses (varies depending on the setting of rinse aid)
25 Drain process 120 sec Maximum time. Time is controlled by level sensor***
Drying
26 Fan 480 sec
27 Signal 4 sec If signal is selected
Explanation
Cleaning
process
*
Cleaning cycle for container 90 sec The circ. pump stops and the drain pump runs for 2 sec. The circ. pump runs for 3
sec. and then rests for 5 sec. This repeats a total of eight times, but the fifth time the
circ. pump may rest for 8 sec instead of 5 sec.
Inlet
process
**
Inlet process 255 sec The flow meter signals the flow in pulses. The control unit determines the number of
pulses for each inlet. If not 80 pulses has been reached within 60 sec or a specific
number of pulses is not reached within 255 sec, the program will interrupt.
Drain
process
***
Drain process 120 sec The drain pump starts and pumps out until the level sensor reaches a specified value.
After that, the drain pump continues for additional 10 sec. The total time depends on
how long it takes to reach the specified value from the level sensor. If the specified
value is not reached within 120 sec, the program will interrupt.