Back to the Basics Page 40
Adjusting The Cooling Fan Cutout Temperature
Dacor wall ovens and ranges come preset with the cooling fan cut out preset at 300f. Please note
that 300f. and the indication 000 are the same.
In certain applications, (high or low ambient temps or high altitude) you may want to modify the
default setting of the cooling fan cutout temperature. It can be adjusted from 450f. to 200f. To
modify the setting, please perform the following sequence waiting no more than three seconds
between keystrokes.
Press broil keypad
Press the plus temperature keypad
Press and hold the broil keypad until the display indicates three red numbers on the right
side of the display
Once the cutout temperature is displayed use the plus or minus temperature keypads to
raise or lower the setting
Press cancel secure