1. The maximum gas supply pressure to the
regulator must not exceed 1/2 pound per square
inch.
2. Verify proper gas supply has been provided. Refer
to Tabe 1, Page 6.
3. Do not apply excessive pressure when tightening
connections and fittings.
4. Do not use plumber’s putty or Teflon tape on gas
compression connections. It can defeat the proper
sealing of these fittings. Use plumbers putty or
Teflon tape only on pipe thread fittings.
5. Turn all outdoor grill control valves to the “OFF”
position, then turn on the gas supply. Check all
supply lines and connections for leaks using a
soap and water solution. Do not use a flame to
check leaks. After verifying that there are no gas
leaks, turn off the gas supply to the grill by turning
the gas shut-off valve to the “OFF” position.
Leak testing of the appliance shall be conducted
according to the manufacturer’s instructions.
6. For LP cylinder installations, the LP gas cylinder
must have its own Certified high-pressure
regulator (Either Type I or No. 600 Connection).
7. Natural gas installations will be connected to
factory supplied natural gas regulator. Refer to
Natural gas connections in this manual for details.
8. Inspect the gas line before and after installation.
Also, inspect the line for damage before each use
of the outdoor grill.
Gas Supply Requirements
WARNING
in s T a l l a T i o n spe C ifi C a Tio n s
NOTES:
1. No adjustment of burner settings is required.
All valves and air mixture shutters found in this
appliance have been factory preset.
2. Liquid propane (LP) grills should be special
ordered from the factory. Liquid propane units are
identified by the “LP” designation at the end of
the model number on the product identification
chassis tag.
3. Under extenuating circumstances, outdoor grills
may be field converted to operate on LP gas or at
elevations in excess of 5,000 feet above sea level.
However, field conversion must be completed
by a qualified service agency and authorization
must be granted by the factory prior to any field
conversion.
4. To prevent damage to the gas regulator, install
the regulator only after the grill is mounted in
its permanent position in the enclosure or cart.
Ensure the arrow on the regulator points in the
direction of the gas flow towards the grill.