(TROUBLE 5) NO MICROWAVE OSCILLATION EVEN THOUGH FAN MOTOR ROTATES.
For KOR-61AP0S, KOR-81AP0S
Replace
Check continuity
of primary wind-
ing
of high voltage
transformer and
touch control
circuit
Turn table motor,
fan motor and
oven lamp turn
on for a
second when
the start pad
is tapped
No
Conntinuity
Open winding
Replace Normal
Defective touch
control circuit
Check continuity
of connecting wire
of magnetron.
No microwave
oscillation
Continuity
Replace
Check the isola-
tion
of filament wind-
ing of high voltage
transfrmer
No
Good
Defective
high voltage
transformer
Replace
Good
No
Continuity
Defective
magnetron
Replace
Check continuity
of filament of
magnetron.
No
Continuity
Defective
magnetron
Replace
Check the isola-
tion
of filament termi-
nal of high voltage
transformer
No
Continuity
Defective
high voltage
transformer
Replace
Check the diode
for continuity
in the reverse
and normal
directions
Continuity
in the
reverse
direction
Defective
high voltage
diode
Continuity
Continuity
CHECK RESULT
CAUSE REMEDY
CONDITION
CHECK RESULT
CAUSE REMEDY
CONDITION