5.5. Actuator test
If user selects the
item in DIAGNOSIS ITEM, user can see
item as shown on the right :
If user press No.key, refer to the item, user
can do actuator test.
F1, : Increase the prestroke
actuator operation (target
position)
F2, : Decrease the prestroke
actuator operation (target
position)
F3, : Stop the prestroke actuator
operation
In case, engine is not operation condition. the screen is as follows :
To cancel, press the key.
5.6. Flight record
The flight record mode allows for the dis-
play and recording of data generated by
the ECU as determined by the user of
Scan Pole.
If user selects the in
then display as
shown on the right
The function of the
facility is determined by the following func-
tion key.
1) F1, : Select item.
2) F2, : Flight record
3) F3, : Adjust interval of recording time (0.1 - 10.0sec)
4) F4, : RECORD data output.
5) F5, : RECORD data graph output
6) F6, : RECORD data printing
User can adjust interval of recording time using F3, key.(Time Interval : 0.1~10.0 sec)
TIME
PRINT
GRAPH
OUTPUT
TIME
RECORD
SELECT
FLIGHT RECORD
DIAGNOSIS ITEM
FLIGHT RECORD
ESC
Now it is not engine running
Please starting engine!
STOP
-
+
ACTUATOR TEST
- 147 -
ACTUATOR TEST
1. PRESTROKE ACTUATOR TEST
2. TACHO METER TEST
3. AIR HEATER LAMP TEST
4. AIR HEATER RELAY TEST
5.DIAGNOSTICS LAMP TEST
Press Key,refer to the item.
PRESTROKE ACTUATOR TEST
ENGINE RPM..........................................RPM
PRESTROKE TARGET................................V
PRESTOKE ACTUAL...................................V
PRESTROKE OFFSET................................ V
PRESTROKE SHUT-OFF........................OFF
----
CONONDITION : IDLE,WARM-UP
METHOD : 1.Check on ENG.RPM
2.Check on sensor,relay
3.Compare target position with
actual position
STOP-+
FLIGHT RECORD
02 FUEL RACK SENSOR........................V
03 PRESTROKE TARGET.......................V
04 PRESTROKE ACTUAL.......................V
05 WATER TEMP.SENSOR...................°C
06 RACK SENSOR OFFSET...................V
07 PRESTROKE OFFSET.......................V
08 MEMORY CLEAR SWITCH .........OFF
09 ENGINE START SWITCH. ............OFF
TIME INTERVAL : sec
SELECT RECORD TIME OUTPUT GRAPH PRINT
01 ENGINE RPM.................................RPM