5
Input Control Object Contents Remark
1. Accumulated
work time of
COMP
1. Defrosting
Mode
1. What to consider in determining the defrosting cycle
Total (accumulated) work time of COMP
2. Conditions to start defrosting mode
When total work time of COMP is more than 8, defrosting mode
starts unconditionally.
1-3. Defrosting Cycle
START 2 4 6 7
(Total Work Time of COMP)
8
Input Control Object Contents Remark
1.Defrosting
Cycle
1. COMP
2. F-FAN
3. R-FAN
4. HEATER
1. Defrosting Mode
1) COMP, F/R/C-FAN: Control
1) If Bi-Metal is over 10, Heater turns Off.
2) COMP, F/R/C FAN: Off
1) Pause: 5 minutes
2) COMP, F/C-FAN: Off
3) R FAN: Control
1) COMP, F/R/C FAN: Control
2. Time Chart in Defrosting Mode
3. Output Control & Limit Time of Each Defrosting Mode
1) When defrosting starts COMP and F/R/C-FAN turn Off.
2) R Fan is ON/OFF Controlled in Pause mode.
1-4. Defrosting Mode
Control
Heater Defrosting
Pause
Control
HTR Start HTR Finish
Pause Star
Pause Finish/
CONTROL
HTR
R-FAN
C-FAN
F-FAN
Comp
ON
ON
ON OFF
HTR ON
Control Heate Defrosting Pause Control
COMP ON/OFF OFF OFF ON/OFF
F-FAN ON/OFF OFF OFF ON/OFF
R-FAN ON/OFF OFF ON ON/OFF
HEATER OFF ON OFF OFF
Limit Time If Bi-metal10°C, 5min.
HTR turns Off.