FUNCTIONS
B. Prevention OPTION of EXCESSIVE OR LOW COOLING.
; The input voltage of MICOM and R-Sensor ON/OFF point by changing J3 & R30.
OPTION 3
(P63)
26PIN
CC3
J3
R32
R31
R30
MICOM
5V
Va
Input voltage of MICOM
R-sensor ON/OFF Point
CONTROL OBJECTINPUT
”J3” & “R30” On Main PCB
9. Control of R-sensor OFF Point
+1.7C
5V
J3(CUT), R30(NO USE)
0.3C2.0C
11
+1.4C
4V
J3(CUT), R30 (40.2kohm)
0C1.7C
10
+1.1C
3.3V
J3(CUT), R30 (19.6kohm)
-0.3C1.4C9
+0.7C
2.5V
J3(CUT), R30 (10kohm)
-0.7C1.0C8
+0.4C
2.0V
J3(CUT), R30 (6.65kohm)
-1.0C0.7C7
-0.4C
1.6V
J3(CUT), R30 (4.87kohm)
-1.8C-0.1C6
-0.7C
1.4V
J3(CUT), R30 (3.92kohm)
-2.1C-0.4C5
-1.1C
1.1V
J3(CUT), R30 (2.8kohm)
-2.5C-0.8C4
-1.4C
0.8V
J3(CUT), R30 (2kohm)
-2.8C-1.1C3
-1.7C
0.3V
J3(CUT), R30 (680ohm)
-3.1C-1.4C2
STANDARD0V
--1.4C0.3C1
INPUT VOL.(MAIN PCB)OFFON
Compared to
“STANDARD”
MICOMAPPLICATION
TEMP. STEP “3”
NO
15