FUNCTIONS
Input voltage of MICOM
R-sensor ON/OFF Point
C. Changing Difference between R-sensor “On” point and “Off” point.
; The input voltage of MICOM and R-Sensor ON/OFF DIFF. by changing J4 & R23.
CONTROL OBJECTINPUT
”J4” & “R23” On Main PCB
9. Control of R-sensor OFF Point
OPTION 2
(P64)
27PIN
CC6
J4
R28
R25
R23
MICOM
5V
Va
3.9C
5V
J4(CUT), R23(NO USE)
-1.4C2.5C
11
3.5C
4V
J4(CUT), R23 (40.2kohm)
-1.4C2.1C
10
3.2C
3.3V
J4(CUT), R23 (19.6kohm)
-1.4C1.8C9
2.8C
2.5V
J4(CUT), R23 (10kohm)
-1.4C1.4C8
2.5C
2.0V
J4(CUT), R23 (6.65kohm)
-1.4C1.1C7
2.1C
1.6V
J4(CUT), R23 (4.87kohm)
-1.4C0.7C6
1.4C
1.4V
J4(CUT), R23 (3.92kohm)
-1.C0C5
1.1C
1.1V
J4(CUT), R23 (2.8kohm)
-1.4C-0.3C4
0..7C
0.8V
J4(CUT), R23 (2kohm)
-1.4C-0.7C3
0.4C
0.3V
J4(CUT), R23 (680ohm)
-1.4C-1.0C2
1.7C
0V
--1.4C0.3C1
INPUT VOL.(MAIN PCB)OFFON
DIFFERENCE OF
ON/OFF POINT
MICOMAPPLICATION
TEMP. STEP “3”
NO
16