Alarm Control Panel Installer Manual
33
Press and to alter the options. Press to confirm the setting and move to the next
submenu.
Table 1-12 Communicator programming settings
Set the call mode to PSTN.
Set the maximum number of call attempts that the Communicator will make
to the same telephone number.
It is possible for the called user to block the entire call cycle or only calls to
their number before the maximum number of attempts allowed for in this
programming step is reached (see User Manual).
Set which Areas the PSTN line trouble must be sent to.
Set which Areas the GSM trouble must be sent to.
If GSM module is installed, you need to define the SIM type provider that
your use.
CONTRACT: SIM card with regular contract.
OTHER: Rechargable prepaid SIM card.
Set the Operator number that receives the SIM card balance information.
This parameter can be set only when the SIM TYPE is set to OTHER.
Set the command that can be used to check the SIM card balance.
This parameter can be set only when the SIM TYPE is set to OTHER.
Press to return to the COMMUNICATOR menu. Step 4
Then you can press and to move to the next menu or press to exit from the
Installer Menu.
POWER SUPPLIES 1.23
After entering the Installer Menu, press and to scroll up and down until you reach the Step 1
POWER SUPPLIES menu. See Figure 1-19.
Power supplies Figure 1-19
Press to enter the programming mode. Step 2
Select which Areas the battery alarm event must (such as main power loss, battery low voltage or Step 3
missing) be sent to.