Alarm Control Panel Installer Manual
55
Submenu
Setting
AREAS
Establish which Areas the access code can operate.
PART1
Establish whether the access code can operate Partition 1 and Partition 2
arming types under the selected Areas.
PART2
ARM
Establish whether the access code has the authority to arm or disarm the
Control Panel.
YES
NO
YES LINK 4: The access code can link the output 4 when arming or
disarming.
DISARM
ARMING
Establish whether the code, when armed, activates the system immediately
or leaving Area exit delays.
IMMEDIATE
DELAYED
FORCED ARM
Establish whether the code can arm the system even with alarm detectors
in a not ready status. For example, windows left open deliberately or
defective sensors.
YES
NO
STOP CALL
Establish whether the access code can stop a telephone call when there is
a telephone call in progress.
YES
NO
ZONE STATUS
Establish whether the access code can change the Zone status, for
example, from ACTIVE to DISALED.
YES
NO
REMOTE
Establish whether the access code can control the Control Panel through
telephone call and SMS.
YES
NO
Controlling through App is not affected by this setting.
TIMER
Establish whether the access code is limited to operation only during certain
time period.
There are four TIMERS can be given to the access code, and each TIMER
can select from eight timers that are configured in the system. If you select
0, the access code can operate during the whole period instead of limited
time period.