EasyManua.ls Logo

Dahua DHI-ARC3008C - Page 75

Dahua DHI-ARC3008C
111 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Alarm Control Panel Installer Manual
74
Submenu
Setting
IP ADDRESS
Configure this setting only if DHCP is set to NO.
Set the IP address that the control panel will have within the network.
Consult the network administrator if you do not know the details.
SUBNET
Configure this setting only if DHCP is set to NO.
Set the correct SUBNET that the Control Panel will use to exit the WAN
network (Router). Consult the network administrator if you do not know the
details.
Normally, the standard value is 255.255.255.000.
GATEWAY
Set the GATEWAY address that the control panel will use to exit the WAN
network (Router). Consult the network administrator if you do not know the
details.
Normally, the GATEWAY is the IP address of the Router in the network.
PORT
The WEB PORT that is used for connecting the Alarm Config Tool installed
on PC. The default value is 09000 and cannot be changed.
REMOTE CONF
ON: Allow the Control Panel to connect the Alarm Config Tool.
OFF: Do not allow the Control Panel to connect the Alarm Configu Tool.
Press to return to the TCP/IP NETWORK menu. Step 4
Then you can press and to move to the next menu or press to exit from the
Installer Menu.
LOG EVENT 1.41
After entering the Installer Menu, press and to scroll up and down until you reach the Step 1
LOG EVENT menu. See Figure 1-43.
Log event Figure 1-43
Press to enter the submenu that shows the latest stored event. See Figure 1-44. Step 2
The latest stored event Figure 1-44
The first line shows the event with its number and the date and time.
The second line shows the event details.
Press and to select the log event. Step 3
(Optional) For some events, you can press to extend the display to view more details of the Step 4
event.

Other manuals for Dahua DHI-ARC3008C

Related product manuals