Installation Guide 11
Alarm
Type
Alarm Event Alarm Signal
Input Port
Alarm Signal
Output Port
Alarm Status
door reader
Tamper alarm of no. 3
door reader
RS-485/CASE
Tamper alarm of no. 4
door reader
RS-485/CASE
2.5 DIP Switch
Operate with DIP switch.
Figure 2-13
the switch is at ON position, meaning 1.
the switch is at the bottom, meaning 0.
18 are all 0; the system is started normally.
18 are all 1; the system enters BOOT mode after start.
1, 3, 5 and 7 are 1, while others are 0. After reboot, the system restores factory defaults.
2, 4, 6 and 8 are 1, while others are 0. After reboot, the system restores factory defaults,
but user info is retained.
2.6 Reboot
Insert a needle into reboot hole, press it once to reboot the device.
Reboot button is to reboot the device, rather than modifying configuration.