Service
Manual
RA R32 Split &
multi split M-Series
ESIE16-02B
Indoor unit Outdoor unit
FTXJ-M FTXM-M FTXP-KV FDXM-F RXJ-M RXM-M MXM-M MXM-N

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Daikin 2MXM50M and is the answer not in the manual?

Daikin 2MXM50M Specifications

General IconGeneral
TypeAir conditioner outdoor unit
Multi-split-
Product colorWhite
Gas hose diameter9.5 mm
Drain hose diameter16 mm
Liquid hose diameter6.35 mm
Outdoor unit depth285 mm
Outdoor unit width765 mm
Outdoor unit height550 mm
Outdoor unit weight41000 g
Outdoor unit noise level486.35 dB
Outdoor unit package depth357 mm
Outdoor unit package width900 mm
Outdoor unit package height614 mm
Outdoor unit package weight43000 g
Outdoor unit sound power level62 dB
Current16 A
AC input voltage220 - 240 V
AC input frequency50 Hz

Summary

Part 1. Introduction

Safety Precautions and Symbols

Critical safety warnings, cautions, and graphical symbols for safe operation.

Part 2. Troubleshooting

Error Code Identification Methods

Checking error codes via remote controller and outdoor unit PCB.

Error Code Based Troubleshooting Steps

Step-by-step procedures for resolving specific error codes.

Component Diagnostic Checklists

Procedures for inspecting and verifying key unit components.

Part 3. Repair

Refrigerant Handling and Repair Procedures

Guidelines for safe refrigerant handling, recovery, and repair.

Unit Component Replacement Procedures

Detailed instructions for removing and replacing specific unit parts.