Installation, Operation,
and Maintenance Manual
Trailblazer
Air-Cooled Scroll Chillers
Model AGZ, E Vintage
30 to 240 Tons (100 to 840 kW)
HFC-410A Refrigerant
50/60 Hz
IOM 1206-7
Group: Chiller
Part Number: IOM1206-7
Date: July 2016

Questions and Answers:

Daikin AGZ130E Specifications

General IconGeneral
BrandDaikin
ModelAGZ130E
CategoryChiller
LanguageEnglish

Summary

Installation and Application Information

Operating and Standby Limits

Defines the acceptable temperature and fluid limits for unit operation.

Unit Placement and Clearances

Guidelines for selecting unit location and maintaining necessary service clearances.

Chilled Water Piping

Specifies requirements for field-installed water piping, strainers, and flow switches.

Water Flow Limitations

Explains constant and variable evaporator flow and their limitations.

Evaporator Freeze Protection

Details methods to protect the evaporator from freezing.

High and Low Ambient Operation

Describes operational capabilities and requirements for high and low ambient temperatures.

Electrical Data

Unit Controller Operation

Controller Inputs/Outputs

Detailed listing of controller analog and digital inputs and outputs.

Set Points and Configuration

Configuration of unit and circuit level set points and dynamic ranges.

Security and Passwords

Procedures for accessing and editing unit parameters securely.

Sequence of Operation

Cool Mode Sequence

Step-by-step operational logic for cooling mode.

Ice Mode Sequence

Step-by-step operational logic for ice mode.

Circuit Sequence of Operation

Operational logic for individual refrigerant circuits.

Unit Functions

Evaporator Flow and Freeze Protection

Covers evaporator flow, freeze protection, pump selection, and LWT target.

Unit Capacity Control and Staging

Manages compressor staging, capacity overrides, and demand limits.

RapidRestore® Option

Enables faster startup and loading after power interruptions.

Sound Reduction

Feature to reduce sound levels by limiting condenser fan speeds.

Circuit Functions

EXV Control and Superheat Target

Details EXV control states, superheat targets, and position commands.

Capacity Overrides

Conditions that override automatic capacity control for safe operation.

Alarms

Unit Fault Alarms

Details on alarms related to power, flow, freeze protection, and sensors.

Compressor Module Communication Alarms

Alarms indicating communication failure with compressor modules.

Unit Problem Alarms

Alarms related to pump failures and communication issues.

Unit Warning Alarms

Warnings for external events, demand limit, and LWT reset inputs.

Circuit Fault Alarms

Faults related to low/high pressure, sensors, and pumpdown.

Using the Controller

Optional Low Ambient Fan VFD

Startup and Shutdown Procedures

Component Operation

Unit Maintenance

Troubleshooting Chart

Warranty Registration Form

Limited Product Warranty