Daikin AKZ439 - User Manual

Daikin AKZ439
48 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Built-in breaker
model
Built-in tank
model
Different-voltage
model
CE model
Built-in heater
model
Installation
Models
Oil Cooling Unit and Accessories
4
Precautions for Installation 6
Method of Transportation / Conveyance / Storage
5
Reference for Pipe Selection 7
Electric Wiring 8
CONTENTS
1
Circulating type
Standard
model
Menu
Series
Built-in
breaker
model (–B)
CE model
(–C)
Built-in
heater
model (–H)
Built-in
tank model
(–T)
Different-
voltage
AKZ149
AKZ329
AKZ439
Instruction Manual
AKZ9 Series
If the air filter is clogged, the cooling performance deteriorates,
causing excess power consumption.
Clean the air filter periodically to reduce power consumption.
Thank you for purchasing DAIKIN Oil Cooling Unit (“OILCON”).
This instruction manual includes instructions for using the Oil
Cooling Unit.
To ensure proper use of this product, be sure to read through this
instruction manual before using it.
After reading this manual, keep it handy for your future reference.
Monitor Items 23
Timer Operation 24
Additional Setting Functions 25
Setting Additional Function 27
For Temperature Control Improvement 30
Alarm/Warning Output Logic 33
Alarm Settings for Optional Protection
Devices (Installed by User) 33
Handling
Before Operation
13Model Identification and Specifications
14
Part Names and Functions 15
Names and Functions of the Control Panel Parts
16
Checking Initial Operating Conditions 18
Operation Setting 19
Holding Constant Oil Temperature 20
Tuning Oil Temperature to Room Temperature
(or Machine Temperature)
21
Cooling Oil at Constant Capacity (%) 22
Optional Parts
Machine temperature tuning control 34
Returned oil temperature control 35
Communication with main machine 36
Maintenance
37
38
Maintenance/Inspection
• Daily maintenance/inspection
• Periodic maintenance/inspection
To leave the unit unused for a long period
CE compliance declaration
42CE compliance declaration
Troubleshooting
When the unit operation seems abnormal
although no alarm is activated
When an alarm is activated
When a warning is generated
Safety Precautions
Installation
Procedure
Before
Operation
Useful
Functions
Maintenance
Troubleshooting
Supplement
Document
Optional
Functions
Operating
Procedure
DAIKIN Oil Cooling Unit
(“OILCON”)
Proper use results in power saving
Compliant with
ROHS
PIM00318A
PIM00318A_EN.fm Page -1 Tuesday, October 26, 2010 12:37 PM

Questions and Answers

  • C
    Christy BrockAug 20, 2025
    How to troubleshoot Daikin AKZ439 when the unit doesn't turn on?
    • E
      Ernest PhillipsAug 20, 2025
      If your Daikin Air Conditioner isn't powering on, check if the power cable is properly connected to the power supply terminal. Also, inspect the transformer's wire connection. If the transformer fuse has melted, it is recommended to consult a DAIKIN service center.
  • S
    Stuart BarnettAug 22, 2025
    What to do if my Daikin AKZ439 pump and compressor are running but oil cannot be cooled?
    • H
      heathermaloneAug 22, 2025
      If your Daikin Air Conditioner's pump and compressor are running, but the oil isn't cooling, here are a few things to check: * Ensure there are no obstructions near the air intake or exhaust port. * Clean the air filter. * Verify that the temperature setting is appropriate. If the exhaust air temperature is almost the same as the room temperature while the compressor is running, the refrigerant gas may be low and needs refilling. Also, if the room temperature is high, compare the unit's capacity in the operating temperature range against the catalog to see if you need a model with higher capacity.
  • P
    Patricia RhodesAug 25, 2025
    Why does my Daikin AKZ439 show a high pressure error?
    • B
      Brittney EdwardsAug 25, 2025
      A high pressure error on your Daikin Air Conditioner can occur if the oil or room temperature is too high. Ensure you are using the unit within its specified operating range. Also, make sure there are no obstructions blocking the air intake or exhaust port, maintaining a clear space of at least 500 mm. A clogged air filter can also cause this issue, so clean it. If none of these solve the problem, contact the DAIKIN Contact Center.
  • R
    Russell BaldwinAug 26, 2025
    What to do if oil does not flow in Daikin Air Conditioner, although the pump is running?
    • J
      Jessica GutierrezAug 27, 2025
      If oil isn't flowing in your Daikin Air Conditioner despite the pump running, and the pump sound level is high, check the following: 1. Ensure the pump suction pipe connection is tight. Check the pipe packing and retighten it securely. 2. Clean the suction strainer. If the oil in the oil tank is dirty, replace it. 3. Refill oil into the oil tank if the oil level is low. 4. If there's a large pressure loss in the oil discharge pipe, increase the oil pipe diameter and shorten the pipe length.
  • A
    Alicia EricksonAug 28, 2025
    What causes a compressor high temperature error in my Daikin Air Conditioner?
    • S
      Steven JohnsonAug 28, 2025
      A compressor high temperature error in your Daikin Air Conditioner can be caused by a few factors. First, check if the oil or room temperature is higher than the specified operating range and adjust accordingly. Ensure that there are no obstructions near the air intake or exhaust port that could impede ventilation. Lastly, a dirty air filter or condenser can also lead to this error, so make sure to clean them.
  • M
    Marcus WaltonAug 29, 2025
    What to do if Daikin Air Conditioner compressor does not run, although the pump is running?
    • A
      Ashley WilliamsAug 30, 2025
      If your Daikin Air Conditioner's compressor isn't running even though the pump is, it could be due to several reasons: * The compressor restart prevention timer may be active. Check if the compressor starts after the timer's preset time has elapsed. * The low oil temperature protection device might be activated. Ensure the inlet oil temperature is 5°C or higher for normal operation. * The low ambient temperature protection device could be activated. Make sure the room temperature is 0°C or higher. * The capacity setting might be at 0% (Mode 9). Change the operation mode to a suitable setting.
  • S
    Summer RamseyAug 31, 2025
    What causes the pump over-current relay to activate on my Daikin Air Conditioner?
    • E
      Elizabeth LevineSep 1, 2025
      If the pump over-current relay is activated on your Daikin Air Conditioner, it could be due to several reasons: * The pump might be overloaded with high-viscosity oil. Use an operating fluid that provides 1.4 to 200 mm2/s viscosity within the specified oil temperature range. * The power supply voltage may be too low, causing the pump current to increase. Check if the voltage is within the specified operating range and look for any instantaneous voltage drops when peripheral equipment starts up. * There may be a break in the pump motor wiring (open-phase), or a foreign object caught in the pump, or a fault in the pump motor. In these cases, replace the pump motor.
  • S
    sanchezalecSep 2, 2025
    How to fix DC fan motor lock error on Daikin Air Conditioner?
    • A
      Amy CoxSep 2, 2025
      To address a DC fan motor lock error on your Daikin Air Conditioner, check the following: * Inspect the signal and engine wires between the filter board and the inverter board for any breaks or loose connections, as a drop in DC voltage can cause insufficient fan motor speed. * Examine the connector insertion and wires for breaks, as a fan motor-control board communication error may be the cause. If necessary, replace the control board. * If the DC fan motor is faulty, replace it.
  • M
    Mrs. Jessica WilliamsSep 4, 2025
    Why can't I set the operation on my Daikin AKZ439?
    • T
      Tonya FrostSep 4, 2025
      If you're unable to set the operation on your Daikin Air Conditioner, here are a couple of things to check: * If you see “---” on the data display, the temperature sensor for the selected operation mode may not be connected. Ensure the corresponding temperature sensor is properly connected. * If “---” briefly appears when you press the [ENT] key, the protect switch might be ON. Turn OFF the protect switch (SW1) on the control board.
  • O
    ohartSep 6, 2025
    What to do if Daikin AKZ439 Air Conditioner pump does not run?
    • C
      Craig JordanSep 6, 2025
      If the pump on your Daikin Air Conditioner isn't running, check the following: * Ensure the remote control input ([10]–[11]) is ON by checking the connection of the remote control input. * Verify that the unit isn't set to the operation lock mode. If it is, cancel the Lock mode on the control panel.

Summary

Safety Precautions

Installation Safety

Safety measures and conditions for installing the unit.

Operational Safety

General safety guidelines and warnings for operating the unit.

Installation Guide

Unit Overview and Accessories

Details about the unit and its included accessories.

Transportation and Storage

Guidelines for safely moving and storing the unit.

Site, Piping, and Wiring Setup

Requirements for installation site, oil piping, and electrical connections.

Handling and Operation Setup

Pre-Operation Checks

Checks and procedures before operating the unit.

Component and Control Panel Identification

Identification and description of unit components and control panel.

Operation Modes and Initial Settings

Explanation of operational modes, initial setup, and setting procedures.

Advanced Features and Options

Additional Setting Functions

Configuring advanced features like auto-tuning and warnings.

Optional Parts Integration

Installation and use of optional parts for enhanced functionality.

Maintenance and Troubleshooting

Maintenance Procedures

Routine and periodic checks and cleaning for the unit.

Troubleshooting Guide

Diagnosing and resolving operational issues and alarms.

Compliance Information

CE Compliance Declaration

Declaration of conformity for CE models.

Daikin AKZ439 Specifications

General IconGeneral
BrandDaikin
ModelAKZ439
CategoryAir Conditioner
LanguageEnglish