Break locknut and turn over pressure adjustment valve clockwise until bottomed out.
Press 'mode' and 'return' keys simultaneously to access parameter mode.
Use 'up'/'down' keys to set pressure, then press 'return' to confirm.
Press 'mode' key to display the final desired pressure setting.
Press 'mode' key to enter monitor mode and scroll to N05.
Loosen locknut C, adjust flow control valve D to set motor RPM to 38 (380 RPM).
Lock the locknut C to secure the set motor RPM.
Turn adjustment B counterclockwise until RPM rises above 38, then stop.
Turn adjustment B 3/4 turn clockwise, or half the bottomed-out distance.
Lock locknut A and press 'mode' to return to pressure setting.