Loading...
4 Quick guide
Operation manual
5
EBLA09~16DA + EDLA09~16DA
Daikin Altherma 3 M
4P620243-1 – 2020.06
0000
User
Advanced user pin code
The Advanced user pin code is 1234. Additional menu items for the
user are now visible.
1234
Advanced user
4.2 Space heating/cooling
To turn room temperature control ON or OFF
1 Go to [C.1]: Operation > Room.
Operation
Room
Space heating/cooling
On
On
C.1
2 Set operation to On or Off.
To turn space heating/cooling operation ON or OFF
NOTICE
Room frost protection. Even if you turn OFF space
heating/cooling operation ([C.2]: Operation > Space
heating/cooling), room frost protection –if enabled– will
remain active.
NOTICE
Water pipe freeze prevention. Even if you turn OFF
space heating/cooling operation ([C.2]: Operation >
Space heating/cooling), water pipe freeze prevention
if enabled– will remain active.
1 Go to [C.2]: Operation > Space heating/cooling.
Operation
Space heating/cooling
Tank
Off
On
On
Room
C.2
2 Set operation to On or Off.
To change the desired room temperature
During room temperature control, you can use the room temperature
setpoint screen to read out and adjust the desired room temperature.
1 Go to [1]: Room.
Room
1
2 Adjust the desired room temperature.
+
21°C
1
a b
Room
a Actual room temperature
b Desired room temperature
To change the desired leaving water temperature
You can use the leaving water temperature setpoint screen to read
out and adjust the desired leaving water temperature.
1 Go to [2]: Main zone or [3]: Additional zone.
Main zone
2
Additional zone
3
2 Adjust the desired leaving water temperature.
+
35°C
2
a b
Main zone
+
45°C
3
a b
Additional zone
a Actual leaving water temperature
b Desired leaving water temperature
To change the weather-dependent curve for the space heating/
cooling zones
1 Go to the applicable zone:
Zone Go to …
Main zone – Heating [2.5] Main zone > Heating WD
curve
Main zone – Cooling [2.6] Main zone > Cooling WD
curve
Additional zone – Heating [3.5] Additional zone >
Heating WD curve
Additional zone – Cooling [3.6] Additional zone >
Cooling WD curve
2 Change the weather-dependent curve.