3 | Components
Service manual
208
EBLA09~16DA + EDLA09~16DA
Daikin Altherma 3 M
ESIE20-06A – 2021.03
a L1B
b L2B
c L3B
d Connector X601
e Connector X602
2 Measure the voltage on connectors X601 and X602 on the noise filter PCB.
Result: All measurements MUST be 230VAC ± 10%.
Is the output voltage on the noise filter
PCB correct?
Action
Yes Return to "Checking
procedures"[4204] of the noise filter
PCB and continue with the next
procedure.
No Replace the noise filter PCB, see "Repair
procedures"[4211].
To check if the correct spare part is installed
Prerequisite: First perform all earlier checks of the noise filter PCB, see "Checking
procedures"[4204].
1 Visit your local spare parts webbank.
2 Enter the model name of your unit and check if the installed spare part
number corresponds with the spare part number indicated in the webbank.
Is the correct spare part for the noise
filter PCB installed?
Action
Yes Return to "Checking
procedures"[4204] of the noise filter
PCB and continue with the next
procedure.