1 | General operation
Service manual
8
EBLA09~16DA + EDLA09~16DA
Daikin Altherma 3 M
ESIE20-06A – 2021.03
1 General operation
The low temperature monoblock is a Heat Pump system used for domestic heating
and/or cooling applications and can be combined with a domestic hot water tank.
Outdoor units
The outdoor unit consists of:
Inverter compressor
A switchbox containing necessary PCBs to control the refrigerant part
A hydro box containing all PCBs and hydraulic parts to control the space heating/
cooling and optional domestic hot water preparation
An air cooled heat-exchanger with inverter controlled fan
A refrigerant to water heat exchanger with PWM controlled pump
2 expansion valves (main, and injection)
2 space heating connections (Water IN and Water Out)
System is controlled via MMI2 room interface
Heating mode
The compressor capacity step is defined by the condensing temperature, which is
calculated through the high pressure sensor read-out.
In defrost or oil return operation the heat exchanger functions as a condenser,
while its fan motor is stopped.
Cooling mode
The compressor capacity step is defined by the evaporation temperature, which is
calculated through the low pressure sensor read-out.