Loading...
3 | Components
Service manual
212
EBLA09~16DA + EDLA09~16DA
Daikin Altherma 3 M
ESIE20-06A – 2021.03
a
a
b
d
d
d
c
d
a Heat sink cover screw
b Heat sink cover
c Main PCB mounting plate
d Main PCB mounting plate fixation screw
4 Disconnect all connectors from the main PCB.
5 Cut all cable ties that fix cables to the main PCB mounting plate.
6 Remove all main PCB mounting plate fixation screws.
7 Pull the refrigerant pipe forward and slide the main PCB mounting plate
upwards so that the noise filter PCB on the back side is easily accessible.
CAUTION
The noise filter PCB is still connected. Do NOT completely remove the main PCB
mounting plate.
8 Disconnect all Faston connectors from the noise filter PCB.