Loading...
3 | Components
Service manual
260
EBLA09~16DA + EDLA09~16DA
Daikin Altherma 3 M
ESIE20-06A – 2021.03
c
a b
e df
f
a Clip
b Thermistor
c Thermistor holder
d Insulation
e Thermistor wire
f Tie strap
2 Install the insulation around the thermistor.
3 Fix the insulation and the thermistor wire using new tie straps.
INFORMATION
See the overview of the thermistors at the start of the electrical check procedure and
the "6.2Wiring diagram"[4314] to determine if the specific thermistor is either:
Directly connected to the PCB
Connected to an intermediate connector which is connected to the PCB
4 If connected to an intermediate connector, connect the thermistor connector
to the intermediate connector. If directly connected to the PCB, connect the
thermistor connector to the appropriate PCB.