5 | Operation
User reference guide
32
EHSH/X(B)04+08P30+50EF
Daikin Altherma 3 R ECH₂O
4P678719-1 – 2021.11
t
60°C
00:00 07:00
50°C
15°C
40°C
14:00 21:00
1
3
2
4
6
5
T
t
T
t
Storage tank temperature
t Time
▪ At 14:00 the DHW schedule is programmed to heat up the tank to 60°C.
▪ At 21:00 the DHW schedule is programmed to heat up the tank to 50°C. This
value is valid until 14:00 the next day.
▪ With the higher set temperature, in the afternoon and evening more hot water is
available.
▪ During the morning, you consume hot water and the storage tank temperature
decreases.
▪ When the tank temperature drops below a preset value (=set temperature –
hysteresis value; example 40°C), the tank is heated up to 50°C.
▪ During the afternoon and evening, you consume hot water again and the DHW
tank temperature decreases again.
▪ When the tank temperature drops below a preset value (=set temperature –
hysteresis value; example 50°C), the tank is heated up to 60°C.
5.7.4 To change the domestic hot water temperature
In Reheat only mode, you can use the tank temperature setpoint screen to read
out and adjust the domestic hot water temperature.
1 Go to [5]: Tank.
2 Adjust the domestic hot water temperature.
a Actual domestic hot water temperature
b Desired domestic hot water temperature
In other modes, you can only view the setpoint screen but not modify it.
When weather-dependent operation is used for the tank, the tank temperature is
determined automatically by the outdoor temperature. For more information, see
"5.9Weather-dependent curve"[442].