Installer reference guide
Daikin Altherma – Low temperature split
English
Installer reference guide
Daikin Altherma – Low temperature split
EPGA11DAV3
EPGA14DAV3
EPGA16DAV3
EAVH16S18DA6V(G)
EAVH16S23DA6V(G)
EAVH16S18DA9W(G)
EAVH16S23DA9W(G)
EAVX16S18DA6V(G)
EAVX16S23DA6V(G)
EAVX16S18DA9W(G)
EAVX16S23DA9W(G)

Table of Contents

Other manuals for Daikin Altherma EPGA16DAV3

Questions and Answers

  • L
    Lynn GonzalesAug 19, 2025
    What to do if the backup heater operation is not activated in Daikin Air Conditioner?
    • J
      James MarshallAug 19, 2025
      Check and make sure that: * The backup heater operation mode is enabled. * The backup heater overcurrent fuse has not been turned off; if it has, check the fuse and turn it back on. * The thermal protector of the backup heater has not been activated; if it has, check the water pressure, whether there is air in the system, and the air purge operation, then press the reset button in the switch box.
  • R
    riverapamelaAug 21, 2025
    What to do if the pressure relief valve opens in Daikin Altherma EPGA16DAV3?
    • R
      Rebecca RichardsAug 21, 2025
      The pressure relief valve might open because: * The expansion vessel is broken: Replace the expansion vessel. * The valve of the water circuit towards the expansion vessel is closed: Open the valve. * The water volume in the installation is too high: Make sure that the water volume in the installation is below the maximum allowed value. * The water circuit head is too high: Check the installation requirements. The maximum water circuit head is 10 m.
  • J
    jmayAug 25, 2025
    What to do if the pump is making noise in Daikin Altherma EPGA16DAV3?
    • M
      melissa62Aug 25, 2025
      The pump in your Daikin Air Conditioner might be making noise because: * There is air in the system: Purge air manually or use the automatic air purge function. * The water pressure at the pump inlet is too low: Check and make sure that the water pressure is >1 bar, the water pressure sensor is not broken, the expansion vessel is NOT broken, the valve of the water circuit towards the expansion vessel is open, and the pre-pressure setting of the expansion vessel is correct.
  • M
    Molly NelsonAug 26, 2025
    What to do if the water flow is too low in Daikin Air Conditioner?
    • M
      Miss Lisa DeleonAug 26, 2025
      Check and ensure that: * All shut-off valves of the water circuit are completely open. * The water filter is clean; clean if necessary. * There is no air in the system; purge air if necessary, either manually or using the automatic air purge function. * The water pressure is >1 bar. * The expansion vessel is NOT broken. * The valve of the water circuit towards the expansion vessel is open. * The resistance in the water circuit is NOT too high for the pump.
  • B
    Brian ThompsonAug 27, 2025
    What to do if the system is making gurgling noises after commissioning Daikin Altherma EPGA16DAV3?
    • N
      Natasha JonesAug 28, 2025
      The gurgling noises in your Daikin Air Conditioner system might be caused by: * Air in the system: Purge air from the system. * Various malfunctions.
  • L
    Laura MahoneyAug 30, 2025
    How to fix failing or blocked pressure relief valve in Daikin Altherma EPGA16DAV3 Air Conditioner?
    • J
      Jennifer KingAug 30, 2025
      Flush and clean the complete tank including the piping between pressure relief valve and the cold water inlet and replace the pressure relief valve.
  • M
    Michael SmithSep 1, 2025
    What to do if the unit must start up out of its operation range in Daikin Altherma EPGA16DAV3?
    • C
      Caitlin PerrySep 1, 2025
      If the water temperature is too low, the unit uses the backup heater to reach the minimum water temperature first (15°C). Check and make sure that: * The power supply to the backup heater is correctly wired. * The backup heater thermal protector is NOT activated. * The backup heater contactors are NOT broken.
  • A
    Anthony Daugherty DDSSep 3, 2025
    What to do if there is air in the Daikin Air Conditioner system?
    • K
      Kathryn WoodSep 3, 2025
      Purge air from the system.
  • T
    Tiffany JonesSep 5, 2025
    What to do if various malfunctions occur in Daikin Altherma EPGA16DAV3?
    • W
      Wendy SandersSep 5, 2025
      Check if or is displayed on the home screen of the user interface.
  • B
    Benjamin FriedmanSep 7, 2025
    What to do if the water volume in the installation is too low in Daikin Altherma EPGA16DAV3 Air Conditioner?
    • R
      Ronald CarterSep 7, 2025
      Make sure that the water volume in the installation is above the minimum required value.

Summary

General Safety Precautions

For the Installer

Installation Site Requirements

Requirements for selecting an appropriate installation location for the unit, considering space and ventilation.

Electrical Safety Precautions

Critical safety precautions for electrical connections, including risk of electrocution.

Application Guidelines

Setting Up the Space Heating;Cooling System

Guidelines for configuring the system for space heating and cooling based on room requirements.

Single Room Setup

Setup configurations for single-room heating/cooling using wired or wireless thermostats.

Multiple Rooms - One LWT Zone

Guidelines for setting up a single leaving water temperature zone for multiple rooms.

Multiple Rooms - Two LWT Zones

Instructions for configuring systems with two distinct leaving water temperature zones.

Setting Up an Auxiliary Heat Source

Guidance on integrating an auxiliary boiler for space heating alongside the heat pump.

Setting Up the Domestic Hot Water Tank

Detailed guidance on setting up and configuring the domestic hot water tank system.

Setting Up Energy Metering

Instructions for configuring energy metering using external power meters or internal calculations.

Setting Up Power Consumption Control

How to limit the system's power consumption using various control methods.

Preparation

Preparing the Installation Site

Guidelines for preparing the installation site, including space and environmental considerations.

Preparing Water Piping

Essential requirements and precautions for preparing the water piping system.

Preparing Electrical Wiring

Guidelines and precautions for preparing the electrical wiring before installation.

Installation

Mounting the Outdoor Unit

Step-by-step guide for securely mounting the outdoor unit on its structure.

Mounting the Indoor Unit

Instructions for correctly mounting and positioning the indoor unit.

Connecting the Water Piping

Comprehensive guide on connecting all water piping for the system.

Connecting the Electrical Wiring

Detailed instructions for all electrical wiring connections to the unit.

Connecting the Main Power Supply

Instructions for connecting the main power supply to the unit.

Configuration

Configuration Wizard

Guidance on using the configuration wizard for initial system setup after the first power-on.

Commissioning

Maintenance and Service

Maintenance Safety Precautions

Critical safety precautions to be observed before performing any maintenance or service work.

Troubleshooting

Precautions When Troubleshooting

Essential safety precautions to take before and during troubleshooting activities.

Solving Problems Based on Symptoms

Guides for diagnosing and resolving issues based on observed system symptoms.

Solving Problems Based on Error Codes

A guide to understanding and resolving system issues based on error codes displayed.

Disposal

Technical Data

Daikin Altherma EPGA16DAV3 Specifications

General IconGeneral
BrandDaikin
ModelAltherma EPGA16DAV3
CategoryAir Conditioner
LanguageEnglish