3 Operation
Operation manual
6
EABH/X16DA+9W + EAVH/X16S(U)18+23DA6V+9W
Daikin Altherma 3 H F+W
4P556068-2A – 2019.12
3.3 Turning operation ON or OFF
3.3.1 Visual indication
Certain functionalities of the unit can be enabled or disabled
separately. If a functionality is disabled, the corresponding
temperature icon in the home screen will be greyed out.
Room temperature control
1.6
bar
55
19
42
18
a
1.6
bar
55
19
42
18
b
a Room temperature control ON
b Room temperature control OFF
Space heating/cooling operation
1.6
bar
55
19
42
18
c
1.6
bar
55
19
42
18
d
c Space heating/cooling operation ON
d Space heating/cooling operation OFF
Tank heating operation
1.6
bar
55
19
42
18
e
1.6
bar
55
19
42
18
f
a Tank heating operation ON
b Tank heating operation OFF
3.3.2 To turn ON or OFF
Room temperature control
1 Go to [C.1]: Operation > Room.
Operation
Room
Space heating/cooling
On
On
C.1
2 Set operation to On or Off.
Space heating/cooling operation
NOTICE
Room frost protection. Even if you turn OFF space
heating/cooling operation ([C.2]: Operation > Space
heating/cooling), room frost protection –if enabled– will
remain active.
NOTICE
Water pipe freeze prevention. Even if you turn OFF
space heating/cooling operation ([C.2]: Operation >
Space heating/cooling), water pipe freeze prevention
if enabled– will remain active.
1 Go to [C.2]: Operation > Space heating/cooling.
Operation
Space heating/cooling
Tank
Off
On
On
Room
C.2
2 Set operation to On or Off.
Tank heating operation
NOTICE
Disinfection mode. Even if you turn OFF tank heating
operation ([C.3]: Operation > Tank), disinfection mode will
remain active. However, if you turn it OFF while
disinfection is running, an AH error occurs.
1 Go to [C.3]: Operation > Tank.
Operation
Tank
Off
On
Space heating/cooling
C.3
2 Set operation to On or Off.
3.4 Space heating/cooling control
3.4.1 Setting the space operation mode
About space operation modes
Your unit can be a heating or a heating/cooling model:
If your unit is a heating model, it can heat up a space.
If your unit is a heating/cooling model, it can both heat up and cool
down a space. You have to tell the system which operation mode
to use.
To tell the system which space operation to use, you can:
You can… Location
Check which space operation mode is
currently used.
Home screen
Set the space operation mode permanently. Main menu
Restrict automatic changeover according to
a monthly schedule.

Other manuals for Daikin Altherma EABH16DA9W