4 Installation
Installation manual
7
EHBH/X04+08DA*V7
Daikin Altherma 3 R W
4P618951-1 – 2020.03
4 Installation
4.1 Opening the units
4.1.1 To open the indoor unit
Overview
1 Front panel
2 Switch box cover
3 Switch box
4 User interface panel
Open
1 Remove the front panel.
2 If you have to connect electrical wiring, remove the switch box
cover.
3 If you have to do work behind the switch box, open the switch
box.
4 If you have to do work behind the user interface panel or upload
new software into the user interface, open the user interface
panel.
5 Optional: Remove the user interface panel.
NOTICE
If you remove the user interface panel, also disconnect the
cables from the back of the user interface panel to prevent
damage.
4.2 Mounting the indoor unit
4.2.1 To install the indoor unit
1 Fix the wall bracket (accessory) to the wall (level) with 2 Ø8mm
bolts.