Installation manual
Daikin Altherma 3 R F
English
Installation manual
Daikin Altherma 3 R F
EHFH03S18D▲3V▼
▲= A, B, C, …, Z
▼= , , 1, 2, 3, …, 9

Table of Contents

Questions and Answers

  • M
    Michele ThompsonSep 23, 2025
    Why is my Daikin Heat Pump making gurgling noises?
    • X
      xlopezSep 23, 2025
      If your Daikin Heat Pump system is making gurgling noises after it has been commissioned, it is likely caused by air in the system. Purge the air from the system to resolve this. It may also be due to an incorrect hydraulic balance, so it is recommended to have the installer perform hydraulic balancing to ensure proper flow distribution. If balancing isn't enough, the installer should adjust the pump limitation settings.
  • M
    Michele LandryAug 23, 2025
    Why is my Daikin Altherma EHFH-D3V Heat Pump not sufficiently heating at low outdoor temperatures?
    • J
      Jamie FreemanAug 23, 2025
      If your Daikin Heat Pump isn't sufficiently heating the space at low outdoor temperatures, it could be due to several reasons: * The backup heater operation might not be activated. Ensure the backup heater operation mode is enabled. * The backup heater overcurrent circuit breaker might be off. Turn it back on if it is off. * The thermal protector of the backup heater might be activated. If it has, check the water pressure, whether there is air in the system, and the air purge operation, then press the reset button in the switch box. * The backup heater equilibrium temperature may not be configured correctly. Try increasing the equilibrium temperature to activate the backup heater operation at a higher outdoor temperature.
  • C
    Christopher JacobsonAug 25, 2025
    What to do if Daikin Altherma EHFH-D3V Heat Pump fails?
    • E
      Edward KellyAug 25, 2025
      A Daikin Heat Pump failure can stem from several issues. It could be due to damage to the heat pump itself, in which case you should consult the help text for malfunctions. Another cause might be air trapped within the system, requiring you to purge the air. Also, an incorrect hydraulic balance could be the reason; the installer needs to perform hydraulic balancing to ensure correct flow distribution. Finally, various malfunctions can trigger a failure; check the user interface for error codes and consult the help text for malfunctions.
  • T
    Teresa CollinsAug 26, 2025
    Why is the water at the tap too cold with my Daikin Altherma EHFH-D3V Heat Pump?
    • S
      Stephanie WillisAug 27, 2025
      If the water at the tap is too cold when using your Daikin Heat Pump, it might be because you ran out of domestic hot water due to unusually high consumption. If you need hot water immediately, activate the DHW tank Powerful operation. Keep in mind that this will consume extra energy.
  • K
    Kimberly GarrettAug 27, 2025
    How to fix too cold/hot living room with Daikin Altherma EHFH-D3V Heat Pump?
    • J
      johnsonbarbaraAug 27, 2025
      If you're feeling too cold or too hot in your living room while using the Daikin Heat Pump, here are a few potential solutions: * If the desired room temperature is too low (or high), increase (or decrease) it. * If the desired room temperature cannot be reached, increase the desired leaving water temperature according to your heat emitter type. * If the weather-dependent curve is set incorrectly, adjust the weather-dependent curve.
  • D
    Danielle HansenSep 18, 2025
    What to do if the water at the tap is too cold with Daikin Altherma EHFH-D3V Heat Pump?
    • F
      Felicia VasquezSep 18, 2025
      If the water at the tap is too cold when using your Daikin Heat Pump, it could be due to high consumption of domestic hot water. If you need hot water immediately, activate the DHW tank Powerful operation, but be aware that this uses extra energy. If this issue happens regularly, consider increasing the DHW tank temperature preset value or adjusting the DHW tank temperature schedule to heat the tank to a higher temperature during the day.
  • T
    Tiffany RogersSep 14, 2025
    What causes the water pressure relief valve to leak in my Daikin Heat Pump?
    • P
      Pamela GarciaSep 14, 2025
      If the water pressure relief valve of your Daikin Heat Pump leaks, it could be because dirt is blocking the water pressure relief valve outlet. Check whether the pressure relief valve works correctly by turning the red knob on the valve counterclockwise.
  • A
    Amy GeorgeSep 17, 2025
    Why am I feeling too cold/hot in my living room using Daikin Altherma EHFH-D3V?
    • J
      Judith GarzaSep 17, 2025
      If you're feeling too cold or hot in your living room with your Daikin Heat Pump, it might be due to several reasons. First, check if the desired room temperature is set too low or too high and adjust it accordingly. If the problem continues, the desired room temperature may not be reachable, so increase the desired leaving water temperature based on your heat emitter type. Also, verify that the weather-dependent curve is set correctly and adjust it if necessary.
  • S
    Susan HughesSep 6, 2025
    Why is my Daikin Altherma EHFH-D3V Heat Pump system making gurgling noises?
    • J
      Jared NelsonSep 6, 2025
      If your Daikin Heat Pump system is making gurgling noises after commissioning, it could be caused by air in the system. Purge the air from the system. It can also be caused by various malfunctions. Check if or is displayed on the home screen of the user interface for more information about the malfunction.
  • E
    Emily WaltersSep 3, 2025
    What to do if Daikin Altherma EHFH-D3V is not heating or cooling and water flow is low?
    • B
      Brian Harris Jr.Sep 3, 2025
      If your Daikin Heat Pump isn't heating or cooling as expected, it might be due to low water flow. Ensure all shut-off valves of the water circuit are completely open, the water filter is clean, and there is no air in the system. Also, check that the water pressure is above 1 bar, the expansion vessel is not broken, and the valve towards the expansion vessel is open. Verify that the resistance in the water circuit isn't too high for the pump.

Daikin Altherma EHFH-D3V Specifications

General IconGeneral
TypeAir-to-Water Heat Pump
RefrigerantR-32
Operating Temperature Range (Heating)-20°C to 35°C
Operating Temperature Range (Cooling)10°C to 46°C
Heating Capacity4.0 - 16.0 kW
Cooling Capacity3.50 to 14.00 kW
Energy Efficiency Ratio (Cooling)4.00
Sound Power Level60 dB